General Inspection | 6/17/2020 | 6/17/2020 | 6/17/2020 | | CANC |
Andy J. Long
|
|
|
|
Site Final | 6/17/2020 | 6/17/2020 | 6/17/2020 | P | PASS |
Andy J. Long
|
|
|
Initiial subdivsion work and infrastructure complete. Homes now in progress and permitted separately. No ESC requests, further ESC inspections on this permit.
|
General Inspection | 6/2/2020 | 6/2/2020 | 6/2/2020 | | PASS |
Michael Zawacki
|
|
|
No dust or tracking issues at site. Hillside still not tackified or seeded. Sprinkler flags installed, may be getting ready to install irrigation.
|
General Inspection | 5/8/2020 | 5/8/2020 | 5/11/2020 | | PASS |
Michael Zawacki
|
|
|
Hillside hasn't been seeded. Water being used around site to keep dust down. No issues at site.
|
General Inspection | 4/23/2020 | 4/23/2020 | 4/23/2020 | P | PASS |
Michael Zawacki
|
|
|
Post rain inspection. Hillside shows no damage or rilling. No issues at site, no runoff from bottom.
|
General Inspection | 4/21/2020 | 4/21/2020 | 4/21/2020 | P | PASS |
Michael Zawacki
|
|
|
Hillside is fully tracked. No wattle or hydroseed installed.
|
General Inspection | 4/14/2020 | 4/14/2020 | 4/14/2020 | P | PASS |
Michael Zawacki
|
|
|
Rear hillside is at new grade. Currently tracking slopes. Owner plans on getting landscaper to add wattle and hydroseed.
|
General Inspection | 3/24/2020 | 3/25/2020 | 3/25/2020 | P | PASS |
Michael Zawacki
|
|
|
Hillside grading. Disturbances end about 100' before property boundry. Hillside is being grading to a 2 to 1 slope. No issues.
|
General Inspection | 2/6/2020 | 2/6/2020 | 2/6/2020 | P | PASS |
Michael Zawacki
|
|
|
No new activity on subdivided lots. Currently snow covered.
|
General Inspection | 12/3/2019 | 12/3/2019 | 12/3/2019 | P | PASS |
Michael Zawacki
|
|
|
Wattles still installed on perimeter. Trench work completed, work on first home has begun.
|
General Inspection | 11/19/2019 | 11/19/2019 | 11/19/2019 | P | PASS |
Andy J. Long
|
|
|
Existing vegetation preserved around utiliities and new driveway access. No trackout or discharges. No corrections at this time. New SFH has started on one of the lots and is permitted seperately
|
General Inspection | 11/1/2019 | 11/1/2019 | 11/1/2019 | P | PASS |
Michael Zawacki
|
|
|
Crew on site doing horizontal boring. Boulders for wall staged on site. Nothing leaving site.
|
General Inspection | 10/17/2019 | 10/17/2019 | 10/17/2019 | P | PASS |
Michael Zawacki
|
|
|
Large excavation for seepage bed. Rocks for rockwall on site. Nothing leaving site.
|
General Inspection | 10/2/2019 | 10/2/2019 | 10/2/2019 | P | PASS |
Michael Zawacki
|
|
|
No new activity at site.
|
General Inspection | 9/18/2019 | 9/19/2019 | 9/19/2019 | P | PASS |
Michael Zawacki
|
|
|
Pipe crew is off site. Still some trenches and stockpiles on lot. Wattle runs along perimeter of road. Stockpiles and site disturbances have natural buffer.
|
General Inspection | 8/21/2019 | 8/29/2019 | 8/29/2019 | P | PASS |
Michael Zawacki
|
|
|
All work currently trenching in street. Water/sewer trench work on site, all staging and storage on lot, small entrance. Wattle butted end to end acting as perimeter control. No esc issues at time of inspection.
|
Site Preparation | 8/21/2019 | 8/21/2019 | 8/21/2019 | P | PASS |
Andy J. Long
|
|
|
Tommy ###-####
Permit posted, RP and developer on site. Much of the existing vegetation is supposed to remain, with only .6 acres of disturbed area. Perimeter wattles have been installed along Highland View. Construction entrance rock installed for truck loads. Exisitng asphalt driveway is to remain for this first phase, request that some gutter check bags be installed to treat driveway runoff.
Approved for construction.
|
Site Preparation | 8/8/2019 | 8/8/2019 | 8/12/2019 | P | NR |
Andy J. Long
|
|
|
to be rescheduled for next week by project contact Tommy
|
Routing - Erosion and Sediment | 8/6/2019 | | 8/6/2019 | | PASS |
Andy J. Long
|
|
|
ESC plan approved. Stormwater team is certified. Site preparation inspection is required.
|
Permit Ready to Issue | | | 8/6/2019 | | DONE |
|
|
|
|
Issue & PRINT permit SFD | | | 8/6/2019 | | DONE |
|
|
|
|
Application received | | | 7/10/2019 | | |
|
|
|
|