Permit NumberFIR00-00547
StatusFinaled
Name GRINNELL FIRE PROTECTION
Site Address 5616 W STATE STREET
Project NameSPR PLANTATION PLZA "B"
Customer Number 
ePlanReview 
Description
PLANTATION PLAZA BUILDING B * TO FULLY FIRE SPRINKLER A NEW TYPE VN, 17,975 SQ. FT., ONE STORY RETAIL/OFFICE SHELL BUILDING AND RELATED UNDERGROUND FIRE LINE INSTALLATION. THIS BUILDING IS CONSTRUCTED OF MASONRY EXTERIOR WALLS AND INTERIOR AND ROOF STEEL STRUCTURAL FRAME. THE FIRE SPRINKLERS ARE BEING USED FOR AREA INCREASE. ALL CONSTRUCTION PER THE APPROVED PLANS AND ATTACHED COMMENT LIST. THIS IS A SHELL BUILDING PERMIT ONLY.
BUILDING PERMIT IS: BLD00-01953 *JWA*
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection9/26/20019/26/20019/26/2001PPASS
DetailsJoe Tawney
Added by Inspector: 406 On 9/26/2001 3:49:56 PM
DOC - Permit Finaled9/26/20019/26/20019/26/2001PPASS
DetailsJoe Tawney
Finaled by inspector at 9/26/2001 3:50:04 PM
INSP-Final Inspection1/29/20012/1/20012/1/2001AFAIL
DetailsRick Jackson
Mike ###-#### 2/1/2001 9:45:56 AM water not turned on and couldn't test alarms 2/1/2001 4:11:16 PM
INSP-Sprinkler Rough-in/Hydro12/29/20001/2/20011/2/2001PPART
DetailsJoe Tawney
###-####. 1/2/2001 12:25:50 PM
INSP-Sprinkler Rough-in/Hydro12/28/200012/29/200012/29/2000APART
DetailsJoe Tawney
###-####. OK on supply line flush and OK on above ground hydro test except FDC connection 12/29/2000 2:35:03 PM
INSP-Sprinkler Rough-in/Hydro12/21/200012/22/200012/22/2000APART
DetailsJoe Tawney
###-####. OK to cover anti freeze piping outside of bldg 12/29/2000 2:15:07 PM
INSP-Supply line flush12/13/200012/14/200012/14/2000APART
DetailsJoe Tawney
###-####. OK on underground hydro test 12/15/2000 7:49:27 AM
INSP-Supply line flush12/13/200012/14/200012/14/2000APART
DetailsJoe Tawney
###-####. OK on underground hydro test 12/15/2000 7:49:27 AM
INSP-Sprinkler Rough-in11/22/200011/27/200011/27/2000PPART
DetailsRick Jackson
underground fire main ###-#### /// okay to cover fire service main 11/27/2000 3:26:20 PM
Issue permit  10/16/2000 DONE
Sprinkler Plan Check10/4/2000 10/10/2000 PASS
DetailsBill Alexander
Remote Area number 1 may appear undersized (even allowing for NFPA-RAF of 32% with a 15'-2" roof)?
Inspection Record Card- Bld10/10/200010/10/200010/10/2000 DONE
Telephone call  10/10/2000 DONE
called permit ready
PLANS/APPL TAKEN TO FRONT DESK  10/10/2000 PASS
DetailsBill Alexander
Plan assigned to (Bill)9/18/2000 10/10/2000 DONE
DetailsBill Alexander
10/10/2000 10:27:10 JWA - activity updated through activity FIRA22 from case FIR00-00547.
Sprinkler Plan Check9/18/2000 10/3/2000 FAIL
DetailsBill Alexander
OVERHEAD* Node reference points on the plans do not match calculations submitted.
Telephone call  10/3/2000 DONE
DetailsBill Alexander
Called Rand and indicated I cannot follow the node numbering system (calculations). They do not match the plans.
Sprinkler Plan Check9/18/2000 9/20/2000 PASS
DetailsBill Alexander
UNDERGROUND* REVIEWED FOR INSTALLATION. OVERHEAD TO BE REVIEWED AT A LATER DATE IN SCHEDULE.
Telephone call  9/20/2000 DONE
DetailsBill Alexander
COPY OF UNDERGROUND REVIEW FAXED TO GRINNELL.
Application received  9/18/2000 PASS
DetailsBill Alexander
Case Summary    DONE