Permit Information
Permit NumberFIR00-00598
StatusFinaled
Name COMMERCIAL FIRE PROTECTION
Site Address 2323 S FEDERAL WAY
Project NameSPR DYKES ELECTRIC INC.
Customer Number 
ePlanReview 
Description
(DYKES ELECTRIC, INC.) TO FIRE SPRINKLER A NEW 12,250 S.F., ONE STORY WAREHOUSE ADDITION TO THE SOUTH SIDE OF THE EXISTING DYKE'S ELECTRIC, INC. WAREHOUSE AND OFFICE BUILDING. THE WAREHOUSE WILL BE FOR STORAGE OF ELECTRIC MOTORS AND RELATED COMPONENTS. THIS ADDITION IS BEING SEPARATED FROM THE EXISTING BUILDING BY A FOUR-HOUR FIRE-RESISTIVE AREA SEPARATION WALL. THIS PERMIT ALSO INCLUDES RELATED FIRE SERVICE MAIN WORK. THIS BUILDING ADDITION IS BEING CONSTRUCTED OF MASONRY EXTERIOR WALLS AND PACIFIC BUILDING SYSTEMS STEEL FRAME AND ROOF SYSTEM. THE ADDITION WILL BE FULLY FIRE SPRINKLED (THE EXISTING BUILDING IS NOT FIRE SPRINKLED). ALL RELATED WORK PER THE APPROVED PLANS, ATTACHED COMMENT LIST AND PER FIRE DEPARTMENT REQUIREMENTS. BLD00-01374, DRH00-00046 *JWA*
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Finaled1/10/20021/10/20021/10/2002PPASS
DetailsRick Jackson
Finaled by inspector at 1/10/2002 4:04:08 PM
INSP-Final Inspection1/11/20011/11/20011/11/2001PPASS
DetailsRick Jackson
Scheduled by a contractor via Hello! on 01/11/2001 at 09:12:19. Contact: ###-####.
INSP-Final Inspection1/2/20011/4/20011/4/2001PFAIL
DetailsRick Jackson
Scheduled by Inspector: 409 On 1/2/2001 10:05:25 AM 1:00 pm------ spare heads; outside control valve; BFP springs require repair kit 1/4/2001 1:44:38 PM
INSP-Final Inspection12/27/20001/2/20011/2/2001ANR
DetailsRick Jackson
Scheduled by a contractor via Hello! on 12/27/2000 at 11:48:58. Contact: ###-####.
INSP-Supply line flush12/11/200012/12/200012/12/2000PPASS
DetailsRick Jackson
Scheduled by a contractor via Hello! on 12/11/2000 at 16:20:55. Contact: ###-####./// supply line flush okay 12/12/2000 3:32:15 PM
INSP-Supply line flush11/3/200011/6/200011/6/2000ACANC
DetailsRick Jackson
Jason ###-####--cancel per david
Issue and Print Permit  11/3/2000 DONE
Issue permit  11/3/2000 DONE
PLANS/APPL TAKEN TO FRONT DESK  11/2/2000 DONE
DetailsBill Alexander
Inspection Record Card- Bld11/2/200011/2/200011/2/2000 DONE
Telephone call  11/2/2000 DONE
talked to Dave Barns ###-#### w/commercial fire protection
Telephone call  11/2/2000 DONE
Faxed copy a passed review to Commercial Fire
Plan assigned to (Bill)10/20/2000 11/2/2000 DONE
11/2/2000 13:42:09 JWA - activity updated through activity FIRA22 from case FIR00-00598.
Sprinkler Plan Check11/1/2000 11/2/2000 PASS
DetailsBill Alexander
Sprinkler Plan Check10/23/2000 10/30/2000 FAIL
DetailsBill Alexander
Building does not conform to UFC Article 81 as designed.
Telephone call  10/30/2000 DONE
Faxed failed review to Commercial Fire.
Application received  10/20/2000  
Case Summary    DONE