Description |
COUNTRY WIDE MORTAGE - To install manual pulls, smoke detection and annunciation within the new TI area, connected to the existing building fire alarm system. Per the 1-line diagram, the existing fire alarm system provides sprinkler system monitoring, limited area smoke detection, and relays to release smoke dampers, fire doors and shut down air handlers on "alarm" condition. The building permit (BLD01-00857) is to finish a 4,608 sq.ft. office tenant in an existing empty space within a 23000 sq ft building. Work to include construction of interior nonbearing partitions which will create an open office area, reception area, work room, break room, conference room and two accessible restrooms, the installation of a suspended ceiling system and miscellaneous related interior finishes. NOTE: This building is fully fire sprinklered for area increase.
|