INSP-Final Inspection | 6/18/2002 | 6/18/2002 | 6/18/2002 | P | PASS |
Troy Cobbley
|
|
|
Underground system finaled
|
DOC - Permit Finaled | 6/18/2002 | 6/18/2002 | 6/18/2002 | P | PASS |
Troy Cobbley
|
|
|
Finaled by inspector at 6/18/2002 4:23:27 PM
|
INSP-Sprinkler Rough-in/Hydro | 4/25/2002 | 4/26/2002 | 4/26/2002 | A | PASS |
Troy Cobbley
|
|
|
3" and 6" risers hydro test OK 4/26/2002 2:52:55 PM
|
INSP-Sprinkler Rough-in/Hydro | 4/25/2002 | 4/25/2002 | 4/25/2002 | P | CANC |
Rick Jackson
|
|
|
INSPECTION CANCELD UNTILL 4-26-02///DLD
|
Override - Parcel Holds | | | 4/25/2002 | | DONE |
Darla L Downs
|
|
|
Parcel Tag Notes: PLAN MODIFICATION ( BLD01-00729) No inspection for rear of meeting rooms. Elevation change to include roof lantern. May cancel parcel tag when Plan Modification is issued. If any questions please contact Mike Phillips. KMM Reason for OverRide:
|
Override - Parcel Holds | | | 4/25/2002 | | DONE |
Darla L Downs
|
|
|
Parcel Tag Notes: PLAN MODIFICATION ( BLD01-00729) No inspection for rear of meeting rooms. Elevation change to include roof lantern. May cancel parcel tag when Plan Modification is issued. If any questions please contact Mike Phillips. KMM Reason for OverRide:
|
Override - Parcel Holds | | | 4/25/2002 | | |
|
|
|
|
INSP-Sprinkler Rough-in/Hydro | 4/23/2002 | 4/24/2002 | 4/24/2002 | A | PASS |
Troy Cobbley
|
|
|
2nd and 3rd floor hydro tests OK 4/24/2002 3:59:34 PM
|
Override - Parcel Holds | | | 4/23/2002 | | DONE |
Annett Moore
|
|
|
Parcel Tag Notes: PLAN MODIFICATION ( BLD01-00729) No inspection for rear of meeting rooms. Elevation change to include roof lantern. May cancel parcel tag when Plan Modification is issued. If any questions please contact Mike Phillips. KMM Reason for OverRide:
|
INSP-Sprinkler Rough-in | 3/5/2002 | 3/6/2002 | 3/6/2002 | A | PART |
Troy Cobbley
|
|
|
Pendant sprinkler heads in linen shaft OK for cover 3/6/2002 10:08:50 AM
|
INSP-Sprinkler Rough-in/Hydro | 2/20/2002 | 2/21/2002 | 2/21/2002 | A | PART |
Troy Cobbley
|
|
|
hydro test and rough-in for the dry stand pipe system OK. Underground still needs to be tested 2/21/2002 11:33:12 AM
|
INSP-Sprinkler Rough-in | 2/11/2002 | 2/11/2002 | 2/11/2002 | P | CANC |
Troy Cobbley
|
|
|
inspection done under FIR01-00396 2/11/2002 3:48:00 PM
|
INSP-Sprinkler Rough-in/Hydro | 1/14/2002 | 1/16/2002 | 1/16/2002 | A | PASS |
Troy Cobbley
|
|
|
Underground flush OK 1/16/2002 9:28:39 AM
|
INSP-Sprinkler Rough-in/Hydro | 1/15/2002 | 1/15/2002 | 1/15/2002 | P | PASS |
Troy Cobbley
|
|
|
Added by Inspector: 430 On 1/15/2002 4:07:17 PM Underground hydro test OK
|
INSP-Sprinkler Rough-in/Hydro | 12/12/2001 | 12/12/2001 | 12/12/2001 | P | PART |
Troy Cobbley
|
|
|
Added by Inspector: 430 On 12/12/2001 3:15:37 PM Heads added in canopy connection to main buiding. OK for cover up. Inspection is for front canopy only
|
INSP-Sprinkler Rough-in | 12/11/2001 | 12/11/2001 | 12/11/2001 | P | FAIL |
Troy Cobbley
|
|
|
this inspection was for front canopy only. heads to be added at connection to building 12/11/2001 12:38:58 PM
|
INSP-Sprinkler Rough-in | 7/17/2001 | 7/18/2001 | 7/18/2001 | P | PART |
Joe Tawney
|
|
|
###-#### OK on 3" main to porte cochere 7/18/2001 1:48:52 PM
|
Sprinkler Plan Check | 7/12/2001 | | 7/13/2001 | | PASS |
Bill Alexander
|
|
|
Porte Cochere underground plan submitted addtion.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/13/2001 | | DONE |
Bill Alexander
|
|
|
Porte Coshere underground added.
|
Telephone call | | | 7/13/2001 | | DONE |
|
|
|
left mess that permit is ready no fees per bill a/mls
|
Telephone call | | | 7/12/2001 | | DONE |
|
|
|
Called 10:00am, and emailed Nick Anderson (National Fire) indicating I need a permit application with this submittal.
|
INSP-Sprinkler Rough-in | 6/27/2001 | 6/28/2001 | 6/28/2001 | P | PART |
Joe Tawney
|
|
|
OK to cover supply line. FDC and Standpipe lines only stubbed 5 ft from riser room.Lines to be run to above ground location later. 6/28/2001 1:59:19 PM
|
Issue and Print Permit | | | 6/25/2001 | | DONE |
|
|
|
|
Issue and Print Permit | | | 6/25/2001 | | DONE |
|
|
|
|
Inspection Record Card- Fire | 6/20/2001 | | 6/20/2001 | | DONE |
|
|
|
|
Telephone call | | | 6/20/2001 | | DONE |
|
|
|
left mess that permit is ready
|
PLANS/APPL TAKEN TO FRONT DESK | | | 6/20/2001 | | DONE |
Bill Alexander
|
|
|
|
Application received | | | 6/19/2001 | | PASS |
Bill Alexander
|
|
|
|
Plan assigned to (Bill) | 6/19/2001 | | 6/19/2001 | | DONE |
|
|
|
6/19/2001 16:22:56 JWA - activity updated through activity FIRA22 from case FIR01-00369.
|
Sprinkler Plan Check | 6/19/2001 | | 6/19/2001 | | PASS |
Bill Alexander
|
|
|
|
Case Summary | | | | | DONE |
|
|
|
|