Information based on query as of Saturday, August 17, 2024.
Permit Information
Permit NumberFIR01-00574
StatusExpired
Name HONEYWELL, INC.
Site Address 190 E BANNOCK ST
Project NameALM-ST LUKES-WEST WING
Customer Number 
ePlanReview 
Description
ST LUKES-WEST WING-2ND FLOOR - This review covers two fire alarm permit numbers, associated with two building permit numbers, being completed as one project. The project is to modify the existing manual and automatic hospital fire alarm system within both TI areas, with new initiating devices and strobes, connected to the existing fire alarm panel #10 which now serves floors B through 4 of this wing, on a new SLC circuit #2. The alarm system includes a manual alarm system, fire sprinkler system monitoring, corridor area smoke detection for release of smoke dampers penetrating corridor walls, induct detectors for release of smoke dampers in other wall, patient room smoke detectors and strobes. Strobes are to be connected to the existing NAC power extender panel connected to FACP #10. Audible alarms are provided by the existing paging system per prior agreement under FIR99-00596. Duct detectors for HVAC are reportedly existing and not included in these permits.
The building permit BLD 01-010843 is to remodel the North portion of the West Wing; area of remodel approximately 3,500 sq.ft. of north 1/2 of the 2nd floor for patient rooms & support areas.
The building permit BLD01-01632 is to remodel a 5,250 sq.ft. area on the south end of the floor for patient rooms, offices, and staff lounge. Work to include construction of interior non-combustible, fire-resistive walls; suspended ceiling grid system; electrical, mechanical, plumbing, sprinkler & alarm system upgrades; three (3) fully accessible patient room units; and interior finishes.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
FIR-Aging Inspection12/23/200212/23/200212/23/2002 PART
DetailsRick Jackson
talked to Mike K. about this project and he said the work hasn't started yet; he will take care of requirements to keep the permit open and talk to Carl Dependahl about it 12/23/2002 9:07:20 AM
Inspection Record Card- Fire11/19/2001 11/19/2001 DONE
Telephone call  11/19/2001 DONE
left mess that permit is ready
Issue and Print Permit  11/19/2001 DONE
Plan assigned to (SAM)10/30/2001 11/16/2001 DONE
11/16/2001 17:13:11 SLR - activity updated through activity FIRA22 from case FIR01-00574.
Alarm Plan Check  11/16/2001 PASS
PLANS/APPL TAKEN TO FRONT DESK  11/16/2001 PASS
Application received  10/30/2001