Permit Information
Permit NumberFIR02-00188
StatusFinaled
Name PEAK ALARM
Site Address 10378 W OVERLAND RD
Project Namealm-FIVE MILE PLAZA
Customer Number 
ePlanReview 
Description
HONKS 99 @ FIVE MILE PLAZA - To install a new fire alarm system to replace 3 existing fire alarm panels and upgrade existing monitoring to meet current code requirements in conjunction with the TI project for Honks Dollar Store. The single new alarm system will cover the entire "building" as defined by UFC 1007, and include monitoring of all sprinkler systems and smoke detectors for HVAC air handler shutdown. The associated building permit (BLD 01-02612) is to remodel of an existing 15,475 sq. ft. space with two mezzanines changing occupancy from an assembly theater to a new retail tenant in existing building per approved plans on file. This shopping center was constructed in Ada County and later annexed into Boise City. Work to include miscellaneous demolition work, upgrading existing 2-hour area separation wall on west side of building by adding a 30" parapet/extending wall through canopy with one-hour soffit protection on each side/CMU wall infill at existing opening, providing a 3/4 hour rated window where required at storefront, new interior steel support beams and columns, new interior column footings, new structural fill and slab to bring floor to one level, masonry infill in interior openings, new storefront windows, new overhead door and opening in exterior wall, upgrading restrooms to meet current accessibility standards, new interior walls and doors, new interior stairway with handrails to electrical equipment mezzanine, interior finish, new suspended ceiling, new draft stops, fire sprinkler work, plumbing work, mechanical work, and electrical work. One mezzanine will be unoccupied and have no use. NOTE: This building is fully fire sprinklered for area increase. No storage racks exceeding 8 ft. in height are allowed under this permit. A CERTIFICATE OF OCCUPANCY IS TO BE ISSUED WHEN COMPLETED AND APPROVED.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection5/17/20025/17/20025/17/2002APASS
DetailsTroy Cobbley
Fire alarm system finaled
DOC - Permit Finaled5/17/20025/17/20025/17/2002APASS
DetailsTroy Cobbley
Finaled by inspector at 5/17/2002 11:00:48 AM
Plan assigned to (SAM)5/3/2002 5/13/2002 DONE
5/13/2002 10:11:42 SLR - activity updated through activity FIRA22 from case FIR02-00188.
Alarm Plan Check5/9/2002 5/13/2002 PASS
REsubmittal acceptable.
PLANS/APPL TAKEN TO FRONT DESK  5/13/2002 DONE
Inspection Record Card- Fire5/13/2002 5/13/2002 DONE
Telephone call  5/13/2002 DONE
SPOKE WITH CLERICE PERMIT READY AND FEES
Override - Parcel Holds  5/13/2002  
tag said not to issue a c of o
Issue permit  5/13/2002 DONE
Alarm Plan Check  5/6/2002 FAIL
Called Steve Larson, Peak Alarm to discuss review concerns but not available; faxed denied review comments to Peak Alarm.
Application received  5/3/2002