Permit Information
Permit NumberFIR02-00363
StatusFinaled
Name C&S FIRE PROTECTION INC
Site Address 159 W THORNBERRY CT
Project NameSPR CHURCHMAN RES.
Customer Number 
ePlanReview 
Description
To fire sprinkler for life Safety a 4,549 ft/2, two-story single family dwelling with a 1,110 ft/2 attached three-car garage. The 1st floor is 3,077 ft/2; the 2nd floor is 1,472 ft/2. This lot is within a hillside area and is subject to the hillside ordinances. Class "A" roof system and 30 ft. defensible space will be maintained. Structure shall be fully fire sprinklered with a system meeting the requirements of NFPA Standard 13D. System to be modified to protect all closets, bathrooms and attached garage. The fire sprinkler flow alarm shall be interconnected to the required residence smoke detection system. All fire sprinkler work and related, which includes dual service water supply, backflow prevention (provided by others), shall be per NFPA 13D, engineering/red-lined plans and attached review notes, as regulated by the Fire Department. This permit is attached to: BLD02-00453.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection2/14/20032/14/20032/14/2003PPASS
DetailsRick Jackson
Scheduled by a contractor via Hello! on 2/14/2003 at 8:21:59 AM. Contact: ###-####.
DOC - Permit Finaled2/14/20032/14/20032/14/2003PPASS
DetailsRick Jackson
Finaled by inspector at 2/14/2003 2:53:31 PM
INSP-Final Inspection2/7/20032/7/20032/7/2003PNR
DetailsRick Jackson
Scheduled by a contractor via Hello! on 2/7/2003 at 11:01:34 AM. Contact: ###-####. will reschedule for 2/10/03 2/7/2003 3:53:59 PM
INSP-Sprinkler Rough-in10/3/200210/4/200210/4/2002APART
DetailsRick Jackson
###-#### okay to cover; riser not complete; sidewalls not installed in garage 10/4/2002 10:03:17 AM
INSP-Sprinkler Rough-in/Hydro10/3/200210/3/200210/3/2002PPART
DetailsTroy Cobbley
First floor sprinklers are OK to cover. Second floor still needs cover inspection. Notified the contractor to double check the distance the sidewall sprinkler heads in the garage are from the ceiling and to provide insulation on vertical risers along garage wall 10/3/2002 2:00:56 PM
INSP-Sprinkler Rough-in/Hydro10/2/200210/3/200210/3/2002AFAIL
DetailsRick Jackson
brian; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie need plans; hangers/straps/tenting not ready 10/3/2002 9:09:01 AM
CHANGE STATUS TO (ISS)  10/2/2002 DONE
permit issued on 9/13/02
Inspection Record Card- Fire9/24/2002 9/24/2002 DONE
Telephone call  9/24/2002 DONE
permit ready
Sprinkler Plan Check9/23/2002 9/23/2002 PASS
DetailsBill Alexander
PLANS/APPL TAKEN TO FRONT DESK  9/23/2002 DONE
DetailsBill Alexander
Issue and Print Permit  9/13/2002 DONE
Inspection Record Card- Fire9/9/2002 9/9/2002 DONE
Telephone call  9/9/2002 DONE
permit ready and fees due
Application received  9/6/2002  
Plan assigned to (Bill)9/6/2002 9/6/2002 DONE
9/6/2002 16:12:11 JWA - activity updated through activity FIRA22 from case FIR02-00363.
Sprinkler Plan Check9/6/2002 9/6/2002 PART
DetailsBill Alexander
OK to proceed. Requires resubmittal prior to 1st inspection.
PLANS/APPL TAKEN TO FRONT DESK  9/6/2002 DONE
DetailsBill Alexander
Case Summary    DONE
Case Summary    DONE