Information based on query as of Saturday, August 17, 2024.
Permit Information
Permit NumberFIR03-00117
StatusFinaled
Name PEAK ALARM
Site Address 3361 N COLE RD
Project Namealm-COLE VILLAGE
Customer Number 
ePlanReview 
Description
FITNESS 19 /COLE VILLAGE SHOPPING CENTER - To install a new fire alarm system for this building, necessary to accommodate the fire alarm monitoring requirements associated with the TI project. The new system will provide monitoring of the fire sprinkler system and of HVAC duct smoke detectors being installed within the TI space for air handler shut down.
The associated building permit (BLD 02-02761) is to remodel to a 7,932 sq.ft. space and changing occupancy from retail to an assembly fitness studio per approved plans on file. Work to include miscellaneous interior demolition work, one-hour rated tenant demising wall infill, exterior wall infill, new interior walls, new interior doors and windows, relocating entrance doors, interior finish, new accessible restrooms, new suspended ceiling, fire sprinkler work, plumbing work, mechanical work, and electrical work. A Certificate of Occupancy is to be issued when completed and approved. NOTE: This building is fully fire sprinklered for area increase. (PC#0716-02) JCB
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection8/15/20038/15/20038/15/2003PPASS
DetailsTroy Cobbley
fire alarm system finaled 8/15/2003 3:23:37 PM
DOC - Permit Finaled8/15/20038/15/20038/15/2003PPASS
DetailsTroy Cobbley
Finaled by inspector at 8/15/2003 3:23:43 PM
INSP-Conference8/6/20038/6/20038/6/2003PDONE
DetailsTroy Cobbley
Peak Alarm requested another copy of the last correction notice. I redid it and delivered it to their office.
INSP-Final Inspection7/30/20037/31/20037/31/2003PFAIL
DetailsTroy Cobbley
There was no test orfice in the anti-freeze system piping of the post office so test could not be completed. The fire alarm system and the water motor gong in Handcock Fabrics did not operate 7/31/2003 4:00:26 PM
INSP-Final Inspection6/26/20036/30/20036/30/2003PFAIL
DetailsTroy Cobbley
The inspectors test orfices in Hancocks Fabrics and the Post Office still do not have the correct orfice installed in the inspectors test lines. Still need test papers 6/30/2003 3:43:07 PM
INSP-Final Inspection6/25/20036/26/20036/26/2003PCANC
DetailsTroy Cobbley
property manager did not show up to provide access 6/26/2003 3:44:24 PM
INSP-Final Inspection6/24/20036/25/20036/25/2003PCANC
DetailsRick Jackson
Scheduled by a contractor via Hello! on 6/24/2003 at 4:55:43 PM. Contact: ###-####. Disp set to [CANC] by a contractor via Hello! on Jun 25 2003 9:14AM.
Inspection Record Card- Fire6/19/2003 6/19/2003 DONE
Telephone call  6/19/2003 DONE
permit ready and no fees due
Issue permit  6/19/2003 DONE
Alarm Plan Check  6/18/2003 PASS
Plan Modification. Approved pending field verification.
PLANS/APPL TAKEN TO FRONT DESK  6/18/2003 DONE
INSP-Final Inspection6/2/20036/3/20036/3/2003AFAIL
DetailsTroy Cobbley
Test the flow switches in the post office, fitness19 and Hancock fabrics. The inspectors tests do not have the correct orfices. Provide approved submittals for the new power supply and test. Provide sign per note #13 6/3/2003 11:26:56 AM
INSP-Final Inspection6/2/20036/2/20036/2/2003PFAIL
DetailsTroy Cobbley
Inspection not complete. To be continued tomorrow. Incorrect items marked on approved plans. 6/2/2003 2:51:59 PM
Inspection Record Card- Fire4/10/2003 4/10/2003 DONE
Telephone call  4/10/2003  
Issue and Print Permit  4/10/2003 DONE
Plan assigned to (SAM)3/12/2003 4/9/2003 DONE
4/9/2003 17:48:09 SLR - activity updated through activity FIRA22 from case FIR03-00117.
Alarm Plan Check  4/9/2003 PASS
PLANS/APPL TAKEN TO FRONT DESK  4/9/2003 DONE
Application received  3/12/2003