Permit NumberFIR03-00202
StatusFinaled
Name SIMPLEX/GRINNELL
Site Address 1055 N CURTIS RD
Project NameSARMC-PARKING GARAGE
Customer Number 
ePlanReview 
Description
To provide new fire alarm control panel for elevator recall.
The associated building permit (BLD 02-02583) is to construct a new 83,600 square foot, two-level, concrete parking garage on the east side of the Saint Alphonsus Regional Medical Center Campus. The top deck being at street level and one below. This garage is an open parking garage with the required exterior openings at the North and East sides of the structure. This building is being structurally designed to support one additional future parking level. This garage is not fire sprinklered. This permit also includes the construction of the related site improvements, including retaining walls, sidewalks and guardrails. All construction per the approved plans and attached comment list.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection10/28/200310/28/200310/28/2003PPASS
DetailsTroy Cobbley
brian; Phone #: ###-#### Internet Inspection Request from: Annette Moore
DOC - Permit Finaled10/28/200310/28/200310/28/2003PPASS
DetailsTroy Cobbley
Finaled by inspector at 10/28/2003 2:59:43 PM
INSP-Final Inspection10/21/200310/27/200310/27/2003AFAIL
DetailsTroy Cobbley
all devices tested ok but there is a problem with the ADT Focus dialer. To sent a signal to the central station it appears a person has to manually push the reset button each time a signal comes comes into the panel. Alarm signals are not getting to central station within the 90 seconds allowed by coded and may not even get there unless that button gets pushed. 10/27/2003 10:10:03 AM
INSP-Final Inspection10/10/200310/14/200310/14/2003ANR
DetailsRick Jackson
Scheduled by a contractor via Hello! on 10/10/2003 at 4:00:18 PM. Contact: ###-####. Call from Brian that they aren't ready and will reschedule for a later date 10/14/2003 9:49:33 AM
INSP-Alarm Testing9/25/20039/25/20039/25/2003PCANC
DetailsTroy Cobbley
per Orlen with Simplexgrinnell the main facp for the hospital has multiple trouble signals including supervisories and a ground fault. Inspection to be called in after problems get solved 9/25/2003 1:52:09 PM
FIR-Aging Inspection8/1/20038/1/20038/1/2003 NR
DetailsTroy Cobbley
work in progress according to Chris with SimplexGrinnell 8/1/2003 10:52:39 AM
Issue and Print Permit  5/2/2003 DONE
Plan assigned to (SAM)4/24/2003 5/1/2003 DONE
5/1/2003 14:07:41 430 - activity updated through activity FIRA22 from case FIR03-00202.
Alarm Plan Check  5/1/2003 PASS
DetailsSam Rogers
Plans approved as noted
PLANS/APPL TAKEN TO FRONT DESK  5/1/2003 DONE
DetailsSam Rogers
Inspection Record Card- Fire5/1/2003 5/1/2003 DONE
Telephone call  5/1/2003 DONE
permit ready and fees due
Application received  4/24/2003