Permit Information
Permit NumberFIR03-00247
StatusFinaled
Name PROTEX
Site Address 500 E BAYBROOK CT Unit: 2,3,& 4
Project Namealm - RIVERVIEW PLAZA-1ST FLR
Customer Number 
ePlanReview 
Description
Add 8 notification appliances to an existing fire alarm system. (ALBERTSONS)(RIVERVIEW PLAZA-1ST FLR-Suites #2, #3, & #4) First floor remodel of an existing 11,397 sq.ft. area for new office and storage use in existing building per approved plans on file. Work to include miscellaneous interior demolition work, providing one-hour 450 degree temperature rated doors in corridor walls and at elevator door openings to comply with code built under to allow stair enclosures to exit into corridor, some new one-hour rated corridor wall portions, a few new one-hour rated interior walls, a few new interior doors, interior finish, a new suspended ceiling portion, some new exit signs and emergency lighting, fire alarm work, mechanical work, plumbing work, and electrical work. A Certificate of Occupancy is to be issued when completed and approved. Suite #2 is 337 sq. ft. Suite #3 is 665 sq. ft. Suite #4 is 10,393 sq. ft. NOTE: This building has an alarm system. This building is NOT fire sprinklered. (PC#0028-02) JCB
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection8/27/20038/27/20038/27/2003APASS
DetailsRick Jackson
DOC - Permit Finaled8/27/20038/27/20038/27/2003APASS
DetailsRick Jackson
Finaled by inspector at 8/27/2003 8:03:08 AM
INSP-Final Inspection8/25/20038/26/20038/26/2003AFAIL
DetailsRick Jackson
8:00 need smoke detector above panel; the plans showed 95 cd strobes and 115 cd strobes were installed - need calcs for battery and voltage drop; need ladder to verify wiring above grid ceiling 8/26/2003 9:51:53 AM
INSP-Final Inspection8/22/20038/25/20038/25/2003ACANC
DetailsRick Jackson
Rick this is Grants cell Thanks have a great weekend; Phone #: ###-#### Internet Inspection Request from: Terry Owsley
INSP-Final Inspection8/21/20038/22/20038/22/2003ANR
DetailsRick Jackson
This is grants Cell Thank you; Phone #: ###-#### Internet Inspection Request from: Terry Owsley per telecon with Bob Cafferty and Rob this will be rescheduled to 8/25/03 8/22/2003 2:51:42 PM
INSP-Final Inspection8/20/20038/21/20038/21/2003ACANC
DetailsRick Jackson
This is Grants Cell Phone. Thanks Have a Great day.; Phone #: ###-#### Internet Inspection Request from: Terry Owsley Inspection cancelled from web by: Terry Owsley
Issue permit  6/2/2003 DONE
Inspection Record Card- Fire5/28/2003 5/28/2003 DONE
Telephone call  5/28/2003 DONE
permit ready
Plan assigned to (SAM)5/20/2003 5/27/2003 DONE
5/27/2003 16:31:31 M_F - activity updated through activity FIRA22 from case FIR03-00247.
Alarm Plan Check  5/27/2003 PASS
Approved pending field inspection of fire alarm permit comments.
PLANS/APPL TAKEN TO FRONT DESK  5/27/2003 DONE
Application received  5/20/2003