Permit Information
Permit NumberFIR04-00096
StatusFinaled
Name DE BEST FIRE PROTECTION
Site Address 510 N 2ND ST
Project NameSPR IDAHO ELKS REHAB BLDG-2 FL
Customer Number 
ePlanReview 
Description
(AUDIOLOGY HEARING CENTER)(IDAHO ELKS REHAB OFFICE BLDG-2ND FLR) To install new and relocate existing fire sprinkler head protection in a new 4,501-ft/2 medical office, located on 2nd floor of 'Shell & Core' building. Fire sprinkler work is related to framing non-combustible, non-bearing walls to create reception/waiting, office's, treatment and support areas and new suspended ceiling grid system all per plans (with possible red-line notes) and all attached plan requiring compliance as specifically applicable to this project. (NOTE: A 510 sq. ft. future tenant space is not being developed under this permit). This building was fully fire sprinklered under BLD03-00653, and attached fire permit FIR03-00557, ('Shell & Core' permits). The fire sprinkler system work shall comply with these conditions, the IFC 2000, the attached review comments, as regulated by the Fire Chief. The review notes, permit and fire "Inspection Card" are required to be on site as a condition of this work, to provide witness of compliance verification of minimum code. This permit is attached to building permit: BLD03-01267.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection6/3/20046/3/20046/3/2004APASS
DetailsRick Jackson
DOC - Permit Finaled6/3/20046/3/20046/3/2004PPASS
DetailsRick Jackson
Finaled by inspector at 6/3/2004 11:43:45 AM
INSP-Sprinkler Rough-in4/13/20044/13/20044/13/2004APASS
DetailsRick Jackson
okay to cover and design area approved per Bill Alexander as shown on plans; will verify spare heads in head box and escutcheons at final 4/13/2004 9:50:07 AM
INSP-Final Inspection4/12/20044/12/20044/12/2004PFAIL
DetailsRick Jackson
contact: Jim; Phone #: ###-#### Internet Inspection Request from: Alicia Pauley Calc'd for treatment room but there is not a door from hallway to treatment room; recalc 4/12/2004 3:40:57 PM
Issue and Print Permit  2/25/2004  
Plan assigned to (Bill)2/12/2004 2/24/2004 DONE
Sprinkler Plan Check2/12/2004 2/24/2004 PASS
DetailsBill Alexander
PLANS/APPL TAKEN TO FRONT DESK  2/24/2004 DONE
Inspection Record Card- Fire2/24/2004 2/24/2004 DONE
Permit Ready to Issue  2/24/2004 DONE
Telephone call  2/24/2004 DONE
spoke with John -- permit is ready.
Application received  2/12/2004