INSP-Sprinkler Rough-in/Hydro | 6/30/2004 | 7/1/2004 | 7/1/2004 | A | PASS |
Rick Jackson
|
|
|
Contact: Mike Leiser - This is a hydro test, would like done around 11 am, please call Mike to confirm 7-1-04; Phone #: ###-#### Internet Inspection Request from: Alicia Pauley Per Bill Alexander the new copper line under the bar canopy will not require sprinkler plan mofications; the semi-portable table canopies will not require sprinklers 7/1/2004 4:06:29 PM
|
DOC - Permit Finaled | 7/1/2004 | 7/1/2004 | 7/1/2004 | P | PASS |
Rick Jackson
|
|
|
Finaled by inspector at 7/1/2004 4:06:35 PM
|
Miscellaneous action | | | 7/1/2004 | | DONE |
|
|
|
Received faxed resubmittal which includes a simple plan and calculations on outside canopy fire sprinkler protection. Consists of operating 4 heads under canopy. Review was not verified, but attached to original approved plan submittal.
|
INSP-Sprinkler Rough-in | 6/14/2004 | 6/15/2004 | 6/15/2004 | A | PART |
Rick Jackson
|
|
|
Contact: Charles -- R-In for Antifreeze loop; Phone #: ###-#### Internet Inspection Request from: Alicia Pauley Met with Charles about getting submittals for sprinklers under the new bar located on the terrace; the new bar was not shown on the resubmittals and is in the calc'd area 6/15/2004 10:31:35 AM
|
Issue and Print Permit | | | 6/14/2004 | | DONE |
|
|
|
|
Sprinkler Plan Check | 6/1/2004 | | 6/10/2004 | | PASS |
Bill Alexander
|
|
|
|
Plan assigned to (Bill) | 6/10/2004 | | 6/10/2004 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 6/10/2004 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 6/10/2004 | | DONE |
|
|
|
|
Inspection Record Card- Fire | 6/10/2004 | | 6/10/2004 | | DONE |
|
|
|
|
Telephone call | | | 6/10/2004 | | DONE |
|
|
|
Left John a voice mail and told him that permit is ready & fees///6/10/04 1:30pm BAM
|
INSP-Sprinkler Rough-in | 6/2/2004 | 6/3/2004 | 6/3/2004 | P | PART |
Rick Jackson
|
|
|
Contact: Charles - Cover Inspection; Phone #: ###-#### Internet Inspection Request from: Alicia Pauley Need to complete the anti-freeze loop when the terrace is ready 6/3/2004 4:18:52 PM
|
INSP-Sprinkler Rough-in/Hydro | 5/27/2004 | 6/1/2004 | 6/1/2004 | A | FAIL |
Rick Jackson
|
|
|
Contact: Charles; Phone #: ###-#### Internet Inspection Request from: Alicia Pauley Heads overspaced in kitchen; tape on heads; need cages on heads in several areas; head in freezer appears to be leaking; need resubmittals for thatch canopies that have heads under them and for changes to under stair piping 6/1/2004 11:30:17 AM
|
Plan resubmittals received | | | 6/1/2004 | | DONE |
|
|
|
|
Issue and Print Permit | | | 4/7/2004 | | DONE |
|
|
|
|
Inspection Record Card- Fire | 3/29/2004 | | 3/29/2004 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 3/29/2004 | | DONE |
|
|
|
|
Telephone call | | | 3/29/2004 | | DONE |
|
|
|
permit ready and fee due
|
Plan assigned to (Bill) | 3/24/2004 | | 3/26/2004 | | DONE |
|
|
|
|
Sprinkler Plan Check | 3/24/2004 | | 3/26/2004 | | PASS |
Bill Alexander
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 3/26/2004 | | DONE |
|
|
|
|
Plan resubmittals received | | | 3/24/2004 | | DONE |
|
|
|
|
Issue and Print Permit | | | 3/22/2004 | | DONE |
|
|
|
|
Plan assigned to (Bill) | 3/17/2004 | | 3/19/2004 | | DONE |
|
|
|
|
Sprinkler Plan Check | 3/17/2004 | | 3/19/2004 | | PART |
Bill Alexander
|
|
|
Plans are denied, work may proceed (without required) inspections. Corrected plans must be resubmitted immediately prior to required inspections.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 3/19/2004 | | DONE |
|
|
|
|
Inspection Record Card- Fire | 3/19/2004 | | 3/19/2004 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 3/19/2004 | | |
|
|
|
|
Telephone call | | | 3/19/2004 | | DONE |
|
|
|
left mess that permit is ready
|
Application received | | | 3/17/2004 | | |
|
|
|
|