Permit NumberFIR04-00322
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 1161 W RIVER ST Unit: 310
Project NameSPR-FOREST RIVER IX-3RD FLR
Customer Number 
ePlanReview 
Description
To replace existing standard sprinklers with QR type, and to relocate and add sprinklers to accommodate new walls, within the TI space. New hydraulic calculations are included for the most remote area of the building sprinkler system(on 3rd floor), to verify a density of 0.10 gpm over 1500 sq ft, using sprinkler head spacing up to 180 sq ft, with 1" dia. armovers from existing sprinkler head outlets.

The scope of the associated building permit BLD04-00813 is: BANNER BANK - FOREST ROVER IX - SUITE 310. This building is fire sprinklered to substitute for 1-hr fire-resistive construction. To remodel a 4,048 square foot office tenant space located on the 3rd floor of a 48,900 square foot building. Work is to include interior nonbearing walls, interior doors, interior windows, suspended ceilings, and interior finishes all per the approved drawings and the plan review conditions on file. In addition, the restrooms located on the 3rd floor will be upgraded to be accessible to the disabled. The location of fire sprinkler heads within this tenant space shall comply with NFPA 13-2002 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection7/13/20047/14/20047/14/2004APASS
DetailsRick Jackson
Don, ###-####
DOC - Permit Finaled7/14/20047/14/20047/14/2004APASS
DetailsRick Jackson
Finaled by inspector at 7/14/2004 8:21:51 AM
INSP-Final Inspection7/12/20047/13/20047/13/2004AFAIL
DetailsRick Jackson
Don, ###-#### Still need QR spare heads 7/13/2004 10:37:06 AM
INSP-Sprinkler Rough-in6/17/20046/18/20046/18/2004APART
DetailsRick Jackson
Don, ###-#### Okay to cover; need QR spare heads in head box 6/18/2004 8:21:27 AM
INSP-Sprinkler Rough-in6/16/20046/16/20046/16/2004PNR
DetailsRick Jackson
jeff; Phone #: ###-#### Internet Inspection Request from: Barbara Moore Received a call from Jeff; he will reschedule when ready 6/16/2004 3:25:32 PM
Inspection Record Card- Fire6/4/2004 6/4/2004 DONE
Permit Ready to Issue  6/4/2004 DONE
Telephone call  6/4/2004 DONE
permit ready and fee due
Issue and Print Permit  6/4/2004 DONE
Sprinkler Plan Check5/25/2004 6/3/2004 PASS
PLANS/APPL TAKEN TO FRONT DESK  6/3/2004 DONE
Application received  5/25/2004