Permit NumberFIR04-00358
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 200 N 4TH ST
Project NameSPR TERRACE PLAZA
Customer Number 
ePlanReview 
Description
(IDAHO CENTRAL CREDIT UNION)(TERRACE PLAZA) * To upgrade/modify the basement fire sprinkler system to meet current construction protection and extend fire sprinkler protection throughout the 1st, 2nd and 3rd floors. Basement fire sprinklers will be completely changed to Q.R.'s and added protection in all concealed combustible areas. The existing riser assembly will be modified to include a new supply main piped though and up into the existing floor janitor's closets with separate floor zone controls and the installation of a double backflow preventer with forward flow appurtenance which will double for a new main drain. A anti-freeze loop system will be installed in the drive-thru canopy. This project has been submitted and reviewed for a change in construction type, as a Type IIIB rather than Type IIIA construction type, since the building is not compliant with 1-hour construction. This fire protection work shall comply with the IFC 2000 and the permit review comments; each regulated by the Fire Chief. The review comments, permit and fire "Inspection Card" are required to be on site as a condition of this work, to provide witness of compliance verification of minimum code. This permit is attached to BLD03-01830.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary  2/3/2006  
INSP-Final Inspection9/14/20059/14/20059/14/2005PPASS
DetailsForrest France
Fire sprinkler permit finaled.
INSP-Final Inspection7/15/20057/15/20057/15/2005PPART
DetailsForrest France
Provide seismic clearance at UG supply where it passes through the foundation wall, provide sinage at riser room door indicating its location.
INSP-Final Inspection6/21/20056/22/20056/22/2005APART
DetailsForrest France
Final pending inspection of heads in one room at the basement level to which access was denied, also need to provide seismic clearance at the underground supply where it passes through the foundation wall.
INSP-Sprinkler Rough-in/Hydro6/8/20056/8/20056/8/2005PPART
DetailsForrest France
Overhead hydrostatic test of basement, first floor, and antifreeze systems passed two hour test.
Issue permit  5/24/2005  
Sprinkler Plan Check5/10/2005 5/20/2005 PASS
DetailsBill Alexander
PLANS/APPL TAKEN TO FRONT DESK  5/20/2005 DONE
Permit Ready to Issue  5/20/2005 DONE
Telephone call  5/20/2005 DONE
tlk to jeff packham ###-#### that permit and fees are ready to be picked up
Plan resubmittals received  5/10/2005 DONE
INSP-Sprinkler Rough-in4/11/20054/11/20054/11/2005PPART
DetailsTroy Cobbley
See plans with todays date for areas ok to cover. Resubmittals are required for changes in piping, lobby and room above ceiling
INSP-Sprinkler Rough-in3/23/20053/23/20053/23/2005PPASS
DetailsTroy Cobbley
Spoke to Mike on phone. Area in question on first floor is ok to cover 3/23/2005 4:00:54 PM
INSP-Sprinkler Rough-in2/25/20052/25/20052/25/2005PPART
DetailsTroy Cobbley
See approved plans for locations in basement where the sprinkler piping is ok to cover. 2/25/2005 3:28:01 PM
INSP-Sprinkler Rough-in2/14/20052/14/20052/14/2005PPART
DetailsTroy Cobbley
See approved plans for first floor locations ok to cover 2/14/2005 4:07:28 PM
INSP-Sprinkler Rough-in2/1/20052/2/20052/2/2005PPART
DetailsRick Jackson
mike; Phone #: ###-#### Internet Inspection Request from: Barbara Moore 2nd and 3rd floors hydro and r/i's all complete 2/2/2005 1:51:23 PM
INSP-Sprinkler Rough-in/Hydro1/31/20051/31/20051/31/2005PPART
DetailsRick Jackson
Mike; Phone #: ###-#### Internet Inspection Request from: Jan Rice 2nd floor r/i and hydro okay 1/31/2005 3:11:11 PM
Inspection Record Card- Fire11/30/2004 11/30/2004 DONE
Telephone call  11/30/2004 DONE
Spoke with Jeff and told him that permit is ready & fees///11/30/04 11:10am BAS
Issue and Print Permit  11/30/2004  
Permit Ready to Issue  11/30/2004 DONE
Plan assigned to (Bill)11/17/2004 11/29/2004 DONE
DetailsBill Alexander
Sprinkler Plan Check11/17/2004 11/29/2004 PASS
DetailsBill Alexander
PLANS/APPL TAKEN TO FRONT DESK  11/29/2004 DONE
Plan resubmittals received  11/17/2004  
INSP-Sprinkler Rough-in/Hydro10/19/200410/19/200410/19/2004PPART
DetailsRick Jackson
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Hydro okay on third floor and main feed from riser to third floor; still need resubmittals and will need to verify piping after approved 10/19/2004 3:39:55 PM
INSP-Sprinkler Rough-in10/15/200410/15/200410/15/2004PFAIL
DetailsRick Jackson
mike; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie Verified piping on third floor hallway only - need resubmittals due to changes and using flexheads 10/15/2004 1:54:01 PM
INSP-Conference8/26/20048/26/20048/26/2004PPART
DetailsRick Jackson
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Met with Mike about the riser for floors - plans show in electrical closet but will not meet clearances from electrical panels per NEC; stair risers may work but will have to maintain IBC clearances at landings; plan modifications will be needed to reflect changes 8/26/2004 1:03:51 PM
Sprinkler Plan Check7/8/2004 7/12/2004 PASS
DetailsBill Alexander
Plan assigned to (Bill)7/8/2004 7/12/2004 DONE
PLANS/APPL TAKEN TO FRONT DESK  7/12/2004 DONE
Inspection Record Card- Fire7/12/2004 7/12/2004 DONE
Telephone call  7/12/2004 DONE
permit ready and fee due
CHANGE STATUS TO (ISS)  7/12/2004 DONE
picked up
Plan resubmittals received  7/8/2004 DONE
Issue and Print Permit  6/28/2004 DONE
Plan assigned to (Bill)6/15/2004 6/25/2004 DONE
Sprinkler Plan Check6/24/2004 6/25/2004 PART
DetailsBill Alexander
General:
1. Provide corrected and clarification of anti-freeze system, which shall include:
a. Drive thru canopy shall be protected with a minimum design of OH-1.
b. Piping plan shall correlate with calculations.
c. Provide location of loop systems tap (which shall correlate with plans).
d. Include supply piping on the basement floor plan and give the location of the same.
e. Add more nodes on the plans for verification and clarification of calcs.
f. Include manufacturer's data submittal of expansion chamber installing.
g. Include the elevation of the backflow device, etc.

Basement:
2. Provide piping section and configuration on main drain, gang drain and forward flow test connection and how and where they will be pipe out of this building. Include auxiliary drain information in the basement.

Plan FP-2, and FP-3
3. 1st floor tree piping in a lobby is not matching any piping design proven in any part of this structure. Provide clarification of what the designer has made to determine this is will meet minimum protection?

4. Clarify what is located in the center of the basement and 1st floor, which are not identified or protected?

5. Provide readable identification of all rooms, areas and ceiling elevations.

6. Clarify the occupancy hazard/use of the concrete decks.

7. Identify all areas with Obstructed Construction on the plans. (This is brought out due to the detail at "TJI" overbuild).

Plan FP-4 and FP-5
8. 1st floor tree piping in a lobby is not matching any piping design proven in any part of this structure. Provide clarification of what the designer has made to determine this is will meet minimum protection?

9. Provide readable identification of all rooms, areas and ceiling elevations.

10. Fire sprinkler head in top of elevator shaft in the southwest corner is overspaced. Protection area of coverage is determined by 8.5.2.1.1.

11. Identify all areas with Obstructed Construction on the plans.
PLANS/APPL TAKEN TO FRONT DESK  6/25/2004 DONE
Inspection Record Card- Fire6/25/2004 6/25/2004 DONE
Permit Ready to Issue  6/25/2004 DONE
Telephone call  6/25/2004 DONE
permit ready and fee due
Telephone call  6/18/2004 DONE
Designer: Jeff Pacham indicated that changes are being made to the plans and he has requrested to hold them for changes, prior to reviewing.
Application received  6/15/2004  
Inspection Record Card- Fire11/30/2004    
Plan assigned to (Bill)5/10/2005    
DetailsBill Alexander