Permit Information
Permit NumberFIR04-00703
StatusFinaled
Name IDAHO FIRE PROTECTION
Site Address 11660 W EXECUTIVE DR
Project NameSPR EXECUTIVE CENTER
Customer Number 
ePlanReview 
Description
(CORAM HEALTH CARE)(EXECUTIVE CENTER) Add fire sprinkler protection for the remodel to combine two former spaces of 4,884-ft/2 and 2,550-ft/2 into one space for a new total area of 7,434-ft/2. The work is for a new tenant with office, production/packaging, and warehouse use. Tenant is a home health care provider with staff and nurses that place and fill prescriptions for drugs, medications, and IV's and deliver them to home bound clients/patients. This fire sprinkler work is related to some miscellaneous interior demolition with new interior walls, new pre-manufactured clean rooms and suspended ceiling work. A Certificate of Occupancy is to be issued when completed and approved. No steel storage racking exceeding 8' in height allowed in the space. No motor vehicles within the building. This building was originally constructed in Ada County and later annexed into Boise City. This building is fully fire sprinklered for area increase. This fire protection work shall comply with the IFC 2000 and the permit review comments; each regulated by the Fire Chief. The review comments, permit and fire "Inspection Card" are required to be on site as a condition of this work, to provide witness of compliance verification of minimum code. This permit is attached to BLD04-02507.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection12/3/200412/3/200412/3/2004PPASS
DetailsTroy Cobbley
fire sprinklers finaled
DOC - Permit Finaled12/3/200412/3/200412/3/2004PPASS
DetailsTroy Cobbley
Finaled by inspector at 12/3/2004 12:21:31 PM
INSP-Sprinkler Rough-in/Hydro11/26/200411/29/200411/29/2004APASS
DetailsTroy Cobbley
Sprinkler piping rough-in is ok. Piping is ok to cover 11/29/2004 3:06:09 PM
Issue and Print Permit  11/23/2004 DONE
Plan assigned to (Bill)11/9/2004 11/22/2004 DONE
Sprinkler Plan Check11/10/2004 11/22/2004 PASS
DetailsBill Alexander
PLANS/APPL TAKEN TO FRONT DESK  11/22/2004 DONE
Inspection Record Card- Fire11/22/2004 11/22/2004 DONE
Permit Ready to Issue  11/22/2004 DONE
Telephone call  11/22/2004 DONE
called Tom Dutkus ###-#### advised plans are ready to pick up & fees are $105.00 JRR 11-22-04
Application received  11/9/2004