Permit Information
Permit NumberFIR04-00726
StatusFinaled
Name DE BEST FIRE PROTECTION
Site Address 2222 S COLE RD
Project NameSPR OH SHELL & CORE AIRWAY PRK
Customer Number 
ePlanReview 
Description
LOT #8, AIRWAY PARK SUBDIVISION - (SHELL & CORE) * The fire sprinkler system work shall comply with the IFC 2000, the attached review comments/conditions, as regulated by the Fire Chief. The review comments/conditions, permit and fire "Inspection Card" are required to be on site as a condition of this work, to provide witness of compliance verification of minimum code. The underground fire service supply was installed under FIR04-00700. This permit is attached to building permit: BLD04-02144.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection4/6/20054/6/20054/6/2005PPASS
DetailsForrest France
Fire sprinkler finaled
INSP-Sprinkler Rough-in/Hydro3/28/20053/29/20053/29/2005APASS
DetailsTroy Cobbley
Overhead hydro test passed 3/29/2005 10:57:29 AM
INSP-Final Inspection3/28/20053/29/20053/29/2005PCANC
DetailsTroy Cobbley
Not ready 3/29/2005 12:32:31 PM
Issue and Print Permit  2/28/2005 DONE
Inspection Record Card- Fire2/28/2005 2/28/2005 DONE
Telephone call  2/28/2005 DONE
lft vm ###-#### that permit and fees are ready to be picked up
Sprinkler Plan Check2/18/2005 2/25/2005 PASS
DetailsBill Alexander
PLANS/APPL TAKEN TO FRONT DESK  2/25/2005 DONE
Plan resubmittals received  2/24/2005 DONE
Issue and Print Permit  12/21/2004 DONE
Sprinkler Plan Check12/14/2004 12/17/2004 PASS
DetailsBill Alexander
Plan assigned to (Bill)12/14/2004 12/17/2004 DONE
PLANS/APPL TAKEN TO FRONT DESK  12/17/2004 DONE
Permit Ready to Issue  12/17/2004 DONE
Inspection Record Card- Fire12/17/2004 12/17/2004 DONE
Telephone call  12/17/2004 DONE
left mess that permit is ready
Plan resubmittals received  12/13/2004 DONE
Inspection Record Card- Fire12/6/2004 12/6/2004 DONE
Permit Ready to Issue  12/6/2004 DONE
Telephone call  12/6/2004 DONE
Left message that permit is ready & fees///12/06/04 9:55am BAS
Issue and Print Permit  12/6/2004 DONE
Plan assigned to (Bill)11/22/2004 12/3/2004 DONE
Sprinkler Plan Check11/22/2004 12/3/2004 PART
DetailsBill Alexander
1. Hanger information provided does not match the construction information in the Building Permit (BLD04-02144) attaching to TJS trusses, etc. Provide correct hanger details/information corresponding with the approved building construction. (BMC 7-01-50 AMENDMENT MODIFYING IFC SECTION 901.2, IFC 105.4.2, NFPA 13:14.1.3[22])

2. Portions of this facility are addressed as a "Spec" Warehouse. Fire sprinkler systems installed in warehouse type buildings commonly referred to as "spec" warehouses where storage heights of combustible materials over 12 feet are possible, but exact commodity and height are unknown, shall meet the following criteria. At a minimum, systems shall be for Class IV commodity, to the maximum available storage height, (allowance for in-rack sprinklers is accepted), with High Temperature Sprinklers at the ceiling. The fire sprinkler design provided does not address this adopted code. Designer shall provide an approved letter from the owner addressing that the commodities and storage use within this facility will be accepted under the limitations of an OH-2 occupancy protection system. It shall be the responsibility of the code official to evaluate all requests for a system layout meeting the requirements for a less hazardous storage configuration. Reference item #7 below (BMC 7-01-56 AMENDMENT ADDING IFC SECTION 903.1.6)

3. Include in the resubmittals, revised calculations that fit the page and do not "word wrap", for clarification and ease of reading. (BMC 7-01-56 AMENDMENT ADDING IFC SECTION 903.1.6)
PLANS/APPL TAKEN TO FRONT DESK  12/3/2004 DONE
Application received  11/22/2004  
Plan assigned to (Bill)2/18/2005    
DetailsBill Alexander