Permit NumberFIR05-00129
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 4103 W QUAIL HILL CT
Project NameSPR KERI / LYNN RESIDENCE
Customer Number 
ePlanReview 
Description
KERI / LYNN RESIDENCE * To install a life safety fire sprinkler system in a new 3000-ft/2, two story single family dwelling with a 1081-ft/2 attached three car garage. This lot is within a hillside area and is subject to the hillside ordinances. Class "A" roof system and 30 ft. defensible space shall be maintained. This structure shall be fitted with a modified 13D sprinkler system, including fire sprinkler barrier protection between garage and living spaces. This system shall be equipped with an alarm initiating device, commonly referred to as a flow switch, and connected to an audible outside alarm. The first floor is 2273-ft/2 and the 2nd floor is 727-ft/2. All fire sprinkler work and related, which includes dual use, single service water supply, the system backflow prevention device (provided by others), shall be per NFPA 13D, approved plans, engineering/red-lining and attached review comments, under direction of the Fire Chief. This permit is attached to: BLD04-02798.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection8/9/20058/9/20058/9/2005PPASS
DetailsTroy Cobbley
fire sprinkler permit finaled
INSP-Supply line flush7/25/20057/25/20057/25/2005PPASS
DetailsTroy Cobbley
Supply line flush passed.
INSP-Sprinkler Rough-in/Hydro4/1/20054/1/20054/1/2005PPASS
DetailsForrest France
Overhead rough in ok to cover.
Inspection Record Card- Fire4/1/2005 4/1/2005 DONE
Telephone call  4/1/2005 DONE
Spoke with Jeff and told him that permit is ready & no fees due///4/1/05 9:30am BAS
Sprinkler Plan Check4/1/2005 4/1/2005 PASS
DetailsBill Alexander
Miscellaneous action  4/1/2005 DONE
Took resubmittals to permit desk for calling and releasing.2nd review-no fee.
Plan resubmittals received  3/29/2005 DONE
Issue and Print Permit  3/25/2005 DONE
Plan assigned to (Bill)3/7/2005 3/22/2005 DONE
Sprinkler Plan Check3/7/2005 3/22/2005 PART
DetailsBill Alexander
1. Fire sprinkler riser closet is considered a "mechanical room" and shall be protected by fire sprinkler protection. Provide and show protection meeting requirements of NFPA 13D-8.6 and 17.5.
2. Backflow preventer identified on the plans is an "Ames" and the data submittal provided is a "Watts"? Clarify and provide correct/correlating information for calculation pressure loss verification. (IFC 104.9, 105.4.2, 901.2)
3. Hydraulic calculations verification for the Main Floor Area, 2 sprinkler heads testing are flawed. The Reliable Model "F3QR", Q.R., Dry HSW 5.6 K-factor (½"), R5734 is a ½" orifice sprinkler with an average 5.6 K-factor rating. Provide revised calc verification for this test and resubmit. (IFC 104.9, 105.4.2, 901.2)
4. Provide data submittals on the Reliable Model "F3QR", Q.R., Dry HSW 5.6 K-factor (½"), R5734. (IFC 104.9, 105.4.2, 901.2)
5. Unless the Laundry room has a ceiling to floor cabinet, the sprinkler head is not protecting all walls (shadowed). Provide clarification of construction. (IFC 104.9, 105.4.2, 901.2)
6. The domestic control shall be connected upstream of the fire sprinkler take-off, (no exceptions). Provide plans the address this requirement. (NFPA 13D-6.2, A.6.2[a], A.6.3[a], IFC 901.2, IFC 105.4.2).
PLANS/APPL TAKEN TO FRONT DESK  3/22/2005 DONE
Inspection Record Card- Fire3/22/2005 3/22/2005 DONE
Permit Ready to Issue  3/22/2005  
Telephone call  3/22/2005 DONE
left mess that permit is ready
Application received  3/7/2005