Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberFIR05-00151
StatusFinaled
Name NORTHWEST SALES COMPANY
Site Address 101 S CAPITOL BLVD
Project Namealm - US BANK-2ND FLR
Customer Number 
ePlanReview 
Description
To provide total area notification coverage in the remodeled areas per the building permit scope as indicated below. Two (2) speaker/strobes will be relocated and two (2) will be added to the support room (203). The existing required manual fire alarm system includes sprinkler monitoring, HVAC shutdown, elevator recall/shutdown, fire/smoke damper control, door release and notification throughout (for high rise). The battery, voltage drop and speaker calculations appear to have sufficient capacity. No written comments, PDS Fire Inspector to field verify proper visual spacing and appropriate dB levels. An updated building map shall be provided at time of inspection.

There associated building permit BLD05-00112 is to remodel conference rooms, to upgrade core restrooms to be accessible to the disabled, and to remodel the elevator lobby located on the 2nd floor of an existing high-rise building. The area of the entire 2nd story is about 14,520 square feet and the occupant load is about 221. Selective nonstructural demolition is also covered under this permit. Work is to include interior nonbearing walls, a relocated folding partition, suspended ceilings, gypsum board soffits, interior doors, finishes, and relocated plumbing fixtures. The fire sprinkler system, fire alarm system, and high-rise life safety systems (and the infrastructure supporting these systems) for the 2nd floor are regulated under the provisions of the 2000 IBC. These systems shall be upgraded throughout the entire floor to comply with current standards unless they are already compliant. If not already existing, fire-safing shall be installed at the perimeter of the 2nd floor between the floor and the spandrel glass. All work shall comply with the 2003 IBC, the 2000 IBC as noted in the upgrade agreements, approved drawings, and the plan review report on file. **CJW** (US BANK - 2ND FLR - CONFERENCE ROOMS, RESTROOMS, ELEVATOR LOBBY) This building is required to be fire sprinklered because it is a high rise.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection6/2/20056/2/20056/2/2005PPASS
DetailsForrest France
Fire alarm finaled.
INSP-Alarm Testing5/25/20055/27/20055/27/2005APASS
DetailsForrest France
Fire alarm finaled.
Issue and Print Permit  3/25/2005 DONE
Plan assigned to (Mary)3/18/2005 3/23/2005 DONE
Alarm Plan Check  3/23/2005 PASS
Approved pending PDS Fire Inspector field verification. No comments written.
PLANS/APPL TAKEN TO FRONT DESK  3/23/2005 DONE
Inspection Record Card- Fire3/23/2005 3/23/2005 DONE
Permit Ready to Issue  3/23/2005  
Telephone call  3/23/2005 DONE
talked to rick groom at ###-#### is ready
Application received  3/18/2005