Permit Information
Permit NumberFIR05-00203
StatusFinaled
Name SHILO AUTOMATIC SPRINKLER CO
Site Address 8740 W FAIRVIEW AVE
Project NameSPR SMALL SMILES OF BOISE
Customer Number 
ePlanReview 
Description
(SMALL SMILES OF BOISE LLC)(FAIRVIEW TECH CENTER) Drop and add new fire sprinkler protection for the remodel of a new 11,332-ft/2 dental clinic located in an existing 69,561-ft/2 building. Fire sprinkler work is related to miscellaneous demolition work, with installation of new one-hour rated fire barrier walls to roof deck, new interior walls, new suspended ceiling system, new restrooms, new quick-response heads throughout the space. This tenant has one-hour rated fire barrier walls on the east and the west and there is an existing 4-hour fire wall to the north. This permit will also have a one-hour rated medical gas room and one-hour rated mechanical room. This building is fully fire sprinklered for area increase and allows non-rated corridors in the space, one-third the overall diagonal for exit separation, does not require draftstopping, and allows the fire barrier walls to be reduced to a one-hour rating. This fire protection work shall comply with the IFC 2003 and the permit review comments; each regulated by the Fire Chief. The review comments, permit and fire "Inspection Card" are required to be on site as a condition of this work, to provide witness of compliance verification of minimum code. This permit is attached to BLD05-00470.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection4/22/20054/25/20054/25/2005APASS
DetailsTroy Cobbley
Fire sprinkler finaled
INSP-Final Inspection4/21/20054/22/20054/22/2005 FAIL
DetailsForrest France
Replace fusible link and solder pendents in entry with QR as noted in plan review comment #10. Provide current inspection tag on riser. Install ceiling tile around pendent heads prior to final. Space head in laundry room for ordinary hazard req.
Issue permit  4/21/2005 DONE
Plan assigned to (Bill)4/6/2005 4/15/2005 DONE
Sprinkler Plan Check4/6/2005 4/15/2005 PASS
DetailsBill Alexander
PLANS/APPL TAKEN TO FRONT DESK  4/15/2005 DONE
Inspection Record Card- Fire4/15/2005 4/15/2005 DONE
Telephone call  4/15/2005 DONE
tlk to trent bice ###-#### that permit and fees are ready to be picked up
Permit Ready to Issue  4/15/2005  
Application received  4/6/2005