Permit NumberFIR05-00368
StatusFinaled
Name SHILO AUTOMATIC SPRINKLER CO
Site Address 10051 W EMERALD ST
Project NameSPR EMERALD TECH BLD #11
Customer Number 
ePlanReview 
Description
EMERALD TECH CENTER - BUILDING #11 (SHELL ONLY) - To install a complete overhead fire sprinkler system in a new 13,140-ft/2, one story concrete tilt-up exterior walls with steel roof system, 140-ft/2 mechanical room at the south side of the building. To building is to be protected for office and miscellaneous storage. This is a 20'-0" (to roof) shell building only. There is no occupancy allowed under this permit. Separate tenant improvement permits are required to finish this building for occupancy. The fire sprinkler system work shall comply with the IFC 2003, the attached review comments/conditions, as regulated by the Fire Chief. The review comments/conditions, permit and fire "Inspection Card" are required to be on site as a condition of this work, to provide witness of compliance verification of minimum code. The underground fire service supply was installed under FIR05-00338. This permit is attached to building permit: BLD05-00916.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection10/6/200610/9/200610/9/2006PPASS
DetailsTroy Cobbley
permit finaled
INSP-Final Inspection10/5/200610/6/200610/6/2006PCANC
DetailsTroy Cobbley
waiting on fire alarm
INSP-Final Inspection10/4/200610/5/200610/5/2006PCANC
DetailsTroy Cobbley
waiting on alarm
INSP-Final Inspection10/3/200610/4/200610/4/2006PCANC
DetailsTroy Cobbley
Waiting on fire alarm
INSP-Sprinkler Rough-in/Hydro9/6/20059/7/20059/7/2005APART
DetailsForrest France
Overhead hydrostatic test passed. Overhead rough-in missing retaining strap on one hanger which was installed while on site, one head appears to be overspaced at the east end from the exterior shell wall, will verify spacing at final.
Issue and Print Permit  7/14/2005 DONE
Plan assigned to (Bill)6/24/2005 7/13/2005 DONE
Sprinkler Plan Check7/7/2005 7/13/2005 PASS
DetailsBill Alexander
PLANS/APPL TAKEN TO FRONT DESK  7/13/2005 DONE
Inspection Record Card- Fire7/13/2005 7/13/2005 DONE
Telephone call  7/13/2005 DONE
called told lilly permit is ready and fees
Permit Ready to Issue  7/13/2005 DONE
Plan resubmittals received  7/7/2005 DONE
Telephone call  6/28/2005 DONE
Left message for trent that plans failed and need picked up///6/28/05 12:30pm BAS
Sprinkler Plan Check6/24/2005 6/27/2005 FAIL
DetailsBill Alexander
1. Fire sprinkler systems installed in warehouse type buildings commonly referred to as "Spec" warehouses; where storage heights of combustible materials are possible over 12'-0" elevation, (Reference IFC Chapter 23), AND exact commodity, height of storage and storage system is unknown; shall be designed and installed according to the following criteria:
A. Minimum fire sprinkler system design shall be for a Class IV commodity, to the maximum available storage height, allowing for in-rack fire sprinklers, with "High Temperature Sprinklers" installed at the roof. It should be noted that if the warehouse is used to store a higher Class Commodity, upgrades to the sprinkler system shall be required.
B. It shall be the responsibility of the Fire Chief to evaluate all requests for a design meeting the requirements for a lower hazard storage configuration. Contact Mr. Dave Miller for approval/ acceptance at: ###-####.
The maximum clear height from floor to bottom of 2' deep trusses is approximately 15-16 feet. Provide revised plans and calculations addressing this minimum required system protection per BMC 7-01-56-903.1.6.
Miscellaneous action  6/27/2005 DONE
Returned failed plans to permit desk for returning and corrections.
Application received  6/24/2005