INSP-Final Inspection | 8/12/2005 | 8/15/2005 | 8/15/2005 | A | PASS |
Troy Cobbley
|
|
|
Fire sprinklers finaled
|
INSP-Sprinkler Rough-in | 8/12/2005 | 8/15/2005 | 8/15/2005 | A | CANC |
Troy Cobbley
|
|
|
rick; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa NEEDS FINAL - RICK
|
Sprinkler Plan Check | 7/15/2005 | | 7/20/2005 | | PASS |
Bill Alexander
|
|
|
|
Miscellaneous action | | | 7/20/2005 | | DONE |
|
|
|
Plans/documents taken to the permit desk for distributing.
|
Telephone call | | | 7/20/2005 | | DONE |
|
|
|
tlk to brad bettencourt ###-#### that permit and no fees ready to be picked up
|
Telephone call | | | 7/20/2005 | | DONE |
|
|
|
lft vm with randy ###-#### that permit and no fees to be picked up
|
Plan resubmittals received | | | 7/15/2005 | | DONE |
|
|
|
taken to Bill
|
Issue and Print Permit | | | 7/13/2005 | | DONE |
|
|
|
|
Plan assigned to (Bill) | 7/1/2005 | | 7/12/2005 | | DONE |
|
|
|
|
Sprinkler Plan Check | 7/1/2005 | | 7/12/2005 | | PART |
Bill Alexander
|
|
|
Several room identifications in this permit area addressed as Lab and Storage. Designer did not address adequate information relating to what kind of lab and what kind of storage is associated in this permit. Laboratory units are classified as Class A (High Fire Hazard), Class B (Moderate Fire Hazard), Class C (Low Fire Hazard), or Class D (Minimal Fire Hazard), according to the quantities of flammable and combustible liquids specified in NFPA 45 Table 2.2.1(a) and Table 2.2.1(b). (See NFPA 45, Appendix D for further information on laboratory unit fire hazard classification.)
When an automatic sprinkler system is installed, depending on the construction of the building, the hazard class of the laboratory unit, the construction of the laboratory unit enclosure, and the area of the laboratory unit, shall be protected in accordance with the following:
(a) Automatic sprinkler system protection for Class A and Class B laboratories shall be in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems, for Ordinary Hazard (Group 2) occupancies.
(b) Automatic sprinkler system protection for Class C and Class D laboratories shall be in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems, for Ordinary Hazard (Group 1) occupancies.
Provide clarification of laboratory and storage in this permit and verify correct protection meeting the same through resubmittals. (NFPA 13-13.8, 45-4.2.1.1, BMC 7-01-50 IFC 901.2, IFC 105.2.1, 105.4.2)
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/12/2005 | | DONE |
|
|
|
|
Inspection Record Card- Fire | 7/12/2005 | | 7/12/2005 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 7/12/2005 | | DONE |
|
|
|
|
Telephone call | | | 7/12/2005 | | DONE |
|
|
|
lft msg with receptionist ###-#### that permit and fees are ready to be picked up
|
Application received | | | 7/1/2005 | | |
|
|
|
|