Permit NumberFIR05-00487
StatusFinaled
Name BENCHMARK CONSTRUCTION
Site Address 11655 W MCMILLAN RD
Project Namealm - Cross of Christ Church
Customer Number 
ePlanReview 
Description
To provide a new fire alarm system that includes sprinkler monitoring, HVAC shutdown, fire/smoke damper control, door release, offsite alarm supervision and notification (voice/evac) throughout. The new fire alarm system will be installed in the existing building will be and the new addition.

The associated building permit (BLD 04-02937) is to construct a 20,506 sq. ft one story addition to an existing 6, 010 sq. ft. church building. Construction will be masonry and wood framing with a 3 hr fire wall separating the two construction types. A 5100 sq. ft. portion of the masonry building addition will be framed for a future second floor but will be unoccupied attic space only under this permit. Other work includes some demo and remodeling to the existing structure, all site improvements and landscaping per approved plans and attachments, *CUP04-00116 Mod. 3. The entire building new and existing will be fully fire sprinklered and used for area and equipped with a fire alarm system. *Cross of Christ Evangelical Lutheran Church*

Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection4/4/20064/4/20064/4/2006PPASS
DetailsTroy Cobbley
permit finaled
INSP-Alarm Testing3/29/20063/31/20063/31/2006APASS
DetailsTroy Cobbley
permit finaled
INSP-Final Inspection3/20/20063/20/20063/20/2006PFAIL
DetailsTroy Cobbley
No review notes on site. Also contractor needs to provide revised drawings which include the two additional duct smoke detectors and the deletion of the ceiling mount a/v's that were located in the existing sanctuary. No items tested.
INSP-Final Inspection1/9/20061/9/20061/9/2006PPART
DetailsTroy Cobbley
A temporary occupancy was given with Dave Hanneman's permission for the church to occupy the new addition so that work can be completed in the existing area.
INSP-Final Inspection1/5/20061/5/20061/5/2006PFAIL
DetailsTroy Cobbley
See back of review comments for a list of items needing correction. This list is only partial as the inspection is not complete. All signals need to be redone since the monitoring account was not set up. An additional pull station is required.
FIR-Aging Inspection12/30/200512/30/200512/30/2005 NR
DetailsTroy Cobbley
work in progress
Permit Ready to Issue  9/30/2005 DONE
Inspection Record Card- Fire9/30/2005 9/30/2005 DONE
Telephone call  9/30/2005 DONE
Spoke with John and told him that permit is ready & fees///9/30/05 9:30am BAS
Issue and Print Permit  9/30/2005 DONE
Plan resubmittals received  9/29/2005 DONE
Received revised matrix from Jon Van Stone.
Plan assigned to (Mary)8/9/2005 9/29/2005 DONE
Telephone call  9/26/2005 DONE
Spoke to Jon Van Stone regarding ceiling heights in the sanctuary, and the matrix needs to be revised. He will fax one.
Plan resubmittals received  9/23/2005 DONE
Received e-mail from John McCarthy defining the communicaiton process for the FACP (DACT, 2 phone lines)
Telephone call  9/14/2005 DONE
Spoke to John McCarthy, (Benchmark Construction) regarding the FA permit application still did not include the required "off-site alarm supervision" checked not the type defined. The plans include a DACT for the FACP so the assumed design is that two phone lines will be connected to the FACP. John stated that the church already has a security system and they wanted to use the same monitoring. He has a meeting today and will call me back tomorrow.

I told him that if they were not going to utilize the FACP with the DACT that they would need to resubmit the design to implement whatever is in place to use for the monitoring and they will need to give the monitoring company's information to me.
Plan resubmittals received  9/7/2005 DONE
Case Summary  9/7/2005 DONE
Alarm Plan Check  8/16/2005 FAIL
Resubmittal required. Faxed comments to Benchmark, E2Co and Fibertechian
Application received  8/9/2005  
Case Summary  8/9/2005 DONE