INSP-Final Inspection | 5/23/2006 | 5/23/2006 | 5/23/2006 | P | PASS |
Troy Cobbley
|
|
|
permit finaled
|
INSP-Final Inspection | 5/23/2006 | 5/23/2006 | 5/23/2006 | P | PASS |
Troy Cobbley
|
|
|
permit finaled
|
INSP-Alarm Testing | 2/13/2006 | 2/13/2006 | 2/13/2006 | P | PASS |
Troy Cobbley
|
|
|
Fire alarm finaled
|
Issue and Print Permit | | | 1/31/2006 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 1/19/2006 | | DONE |
|
|
|
|
Inspection Record Card- Fire | 1/19/2006 | | 1/19/2006 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 1/19/2006 | | DONE |
|
|
|
|
Telephone call | | | 1/19/2006 | | DONE |
|
|
|
lft vm with rick groom ###-#### that permit and fees are ready to be picked up
|
INSP-Final Inspection | 1/17/2006 | 1/17/2006 | 1/17/2006 | P | PART |
Troy Cobbley
|
|
|
A temporary occupancy was given with Dave Hannemans permission until the revised fire alarm plans are approved. Pull stations and a/v's as installed work.
|
Alarm Plan Check | | | 1/17/2006 | | PASS |
|
|
|
Plan Modification. Approved pending field inspection of fire alarm permit comments.
|
Case Summary | | | 1/12/2006 | | DONE |
|
|
|
|
Plan resubmittals received | | | 1/10/2006 | | DONE |
|
|
|
|
INSP-Alarm Testing | 12/20/2005 | 12/21/2005 | 12/21/2005 | A | FAIL |
Forrest France
|
|
|
A door has been added from the assembly area to the storage room disrupting the occupancy separation, this area will now require connection to the voice evac. and visual notification as well. No inspection until plans have been resubmitted and approved with required changes reflecting correct floor plan as installed.
|
Issue and Print Permit | | | 12/9/2005 | | DONE |
|
|
|
|
Alarm Plan Check | | | 12/8/2005 | | PASS |
|
|
|
Approved pending field inspection of fire alarm permit comments.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 12/8/2005 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 12/8/2005 | | DONE |
|
|
|
|
Inspection Record Card- Fire | 12/8/2005 | | 12/8/2005 | | DONE |
|
|
|
|
Telephone call | | | 12/8/2005 | | DONE |
|
|
|
Spoke with Dave and told him that permit is ready & fees///12/08/05 @8:15am BAS
|
Plan assigned to (Mary) | 10/7/2005 | | 12/8/2005 | | DONE |
|
|
|
|
Alarm Plan Check | | | 11/30/2005 | | FAIL |
|
|
|
Resubmittal required. Faxed comments to Rick Groom.
|
Plan resubmittals received | | | 11/30/2005 | | DONE |
|
|
|
|
Plan resubmittals received | | | 11/10/2005 | | DONE |
|
|
|
|
Case Summary | | | 11/10/2005 | | DONE |
|
|
|
|
Alarm Plan Check | | | 10/18/2005 | | FAIL |
|
|
|
Fire alarm system must be extended into the B and S1 areas because the separation requriement is 3 hours (S1 to A) with fire sprinkler reduction of 1 hour, a 2 hours wall is required. Only a 1 hour wall is being constructed. Horn/strobes are acceptable in the B and S1 areas.
|
Case Summary | | | 10/7/2005 | | DONE |
|
|
|
|
Case Summary | | | 10/7/2005 | | DONE |
|
|
|
|