Permit Information
Permit NumberFIR05-00768
StatusFinaled
Name COLLIER'S INTERNATIONAL
Site Address 5010 W OVERLAND RD
Project Namealm - PHASE II of upgrade agre
Customer Number 
ePlanReview 
Description
To provide eight (8) duct smoke detectors as per Phase II (East wing of the shopping center) of the upgrade agreement signed 3/3/2005. This phase is to be completed by 12/31/2005. The plans were to arrive by 9/1/2005 and were actually submitted 11/7/2005.

FIR05-00185 (finaled 9/6/2005) was to upgrade the existing fire alarm system (a single FACP) in the shopping center. (A copy of the upgrade agreement is on sheet F0.0.) A required manual fire alarm system is required in the northwest corner of the center (Mike's Restaurant, Primerica, Calvary Chapel, Stage Coach Theatre and Heart and Home) due to the A occupancy load. The remainder of the shopping center will consist of sprinkler monitoring, HVAC shutdown and cooking hood monitoring. Albertson's has its' own FACP and will be allowed to do so due to the fire barriers that separate fire areas.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection2/21/20062/22/20062/22/2006PPASS
DetailsTroy Cobbley
Permit finaled. Contractor provided verification that the duct smoke detectors mounted in the 90 met the manufactures requirements.
INSP-Final Inspection2/16/20062/21/20062/21/2006PCANC
DetailsTroy Cobbley
Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
INSP-Final Inspection1/18/20061/26/20061/26/2006AFAIL
DetailsTroy Cobbley
Provide holes around the duct detector housings, provide differential test for the roof mounted duct detectors since they are mounted in 90's, test unit that was not working in the flower shop
Case Summary  1/23/2006  
Permit Ready to Issue  1/12/2006 DONE
Inspection Record Card- Fire1/12/2006 1/12/2006 DONE
Telephone call  1/12/2006 DONE
Left voice message for Pete that permit is ready & fees @8:30am on 1/12/06 BAS
Issue and Print Permit  1/12/2006 DONE
Alarm Plan Check  1/11/2006 PASS
Plan Modification. Approved pending field inspection of fire alarm permit comments.
PLANS/APPL TAKEN TO FRONT DESK  1/11/2006 DONE
Plan resubmittals received  1/9/2006 DONE
Issue and Print Permit  11/28/2005  
Alarm Plan Check  11/22/2005 PASS
Approved pending field inspection of fire alarm permit comments.
PLANS/APPL TAKEN TO FRONT DESK  11/22/2005 DONE
Permit Ready to Issue  11/22/2005 DONE
Plan assigned to (Mary)11/7/2005 11/22/2005 DONE
Inspection Record Card- Fire11/22/2005 11/22/2005 DONE
Telephone call  11/22/2005 DONE
Left a voice message for Stephanie that permitis ready & fees///11/22/05 @3:15pm BAS
Telephone call  11/22/2005 DONE
Spoke with Pete and told him permit is ready & fees///11/22/05 @3:20pm BAS
Case Summary  11/7/2005 DONE
Application received  11/7/2005  
Inspection Record Card- Fire11/22/2005