Permit Information
Permit NumberFIR06-00168
StatusFinaled
Name DEBEST FIRE PROTECTION
Site Address 9050 W OVERLAND RD
Project NameSPR UG ANDERSON BLACK EAGLE
Customer Number 
ePlanReview 
Description
Anderson Black Eagle - (Shell & Core Underground) - To install underground fire sprinkler service for a new 32,640-ft/2, two story office and retail shell and core building. Separate fire permit required for overhead shell and tenant improvements for occupancy. The fire sprinkler underground work shall comply with NFPA 13-2002, NFPA 24-2002 the IFC-2003, attached review comment and conditions list, as regulated by the Fire Chief. These notes, permit and fire "Inspection Card" are required to be on site as a condition of this work, to provide witness of compliance verification of minimum fire code. This permit is attached to building permit: BLD05-03105.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection11/8/200611/8/200611/8/2006PPASS
DetailsForrest France
UG fire supply line permit finaled.
INSP-Sprinkler Rough-in/Hydro10/30/200610/30/200610/30/2006PCANC
DetailsTroy Cobbley
todd; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Inspection cancelled from web by: Patricia Smith
Override - Parcel Holds1/1/19001/1/190010/30/2006  
INSP-Sprinkler Rough-in9/13/20069/15/20069/15/2006ACANC
DetailsTroy Cobbley
Wrong inspection number called in. I spoke with Todd about having the correct permit number called in for the work being inspected.
INSP-Sprinkler Rough-in9/13/20069/13/20069/13/2006PCANC
DetailsTroy Cobbley
todd; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley Inspection cancelled from web by: Alicia Pauley
Override - Parcel Holds1/1/19001/1/19009/13/2006  
Override - Parcel Holds1/1/19001/1/19009/13/2006  
INSP-Sprinkler Rough-in/Hydro9/12/20069/12/20069/12/2006PPASS
DetailsTroy Cobbley
Underground hydro test passed
Override - Parcel Holds1/1/19001/1/19009/12/2006  
INSP-Supply line flush9/1/20069/5/20069/5/2006APASS
DetailsTroy Cobbley
Underground flush passed.
Override - Parcel Holds1/1/19001/1/19009/1/2006  
INSP-Sprinkler Rough-in6/26/20066/27/20066/27/2006APASS
DetailsTroy Cobbley
Remaining underground supply piping is ok to cover.
Override - Parcel Holds1/1/19001/1/19006/26/2006  
INSP-Sprinkler Rough-in/Hydro4/24/20064/25/20064/25/2006APART
DetailsTroy Cobbley
This was a partial inspection of the underground. The 6" supply piping from the riser to the first 45 elbow is ok to cover. Per Dave with DeBest the piping will be at 4'-6" below grade even though it is not now. The grade will need to be atleast 3" above the bottom of the tilt up wall that passes over the piping.
INSP-Sprinkler Rough-in/Hydro4/18/20064/19/20064/19/2006ACANC
DetailsTroy Cobbley
Contact: Dave - Would like UG cover inspection for around 11 -- 11:30 if possible.; Phone #: ###-#### Internet Inspection Request from: Alicia Pauley Inspection cancelled from web by: Alicia Pauley
Issue and Print Permit  3/27/2006 DONE
Plan assigned to (Bill)3/13/2006 3/24/2006 DONE
Plan resubmittals received  3/24/2006  
Sprinkler Plan Check3/24/2006 3/24/2006 PASS
DetailsBill Alexander
PLANS/APPL TAKEN TO FRONT DESK  3/24/2006 DONE
Inspection Record Card- Fire3/24/2006 3/24/2006 DONE
Permit Ready to Issue  3/24/2006 DONE
Telephone call  3/24/2006 DONE
left mess that permit is ready
Sprinkler Plan Check3/13/2006 3/15/2006 FAIL
DetailsBill Alexander
Plans Denied:
1. The designer shall provide a plan that is of a clarity and font size that is discernable and readable without undue eye strain or stress with the naked eye. Revise and resubmit for review.

2. Include (all) requirements addressed in NFPA 13-14.1.3(10).

3. Provide Fire Department information which may relate to underground requirements. Fire department connections shall be on the street side of buildings, immediately discernible, fully visible and recognizable from the street or nearest point of fire department apparatus accessibility.
a. It must also be located where exposing fires will not affect it. It must have a clear area around the connections (5'-0") accessible for fire apparatus equipment.
b. It shall be located within 100'-0" of an all-weather fire apparatus access roadway and arranged so that hose lines can be attached to the inlets without interference from nearby objects.
c. The fire department connection to the hydrant shall be a maximum 300 feet for pumper operations.
d. The connections must be installed between 24 inches and 48" above finished grade.
(BMC 7-01-61-IFC 912.2.1.1, IFC 508.5.4, 903.3.7, 912, NFPA 13-8.16.2.4.6, 7.7.2.3, 8.16.2.4.6)

4. It would appear that no outside control valve is being provided. Construction requirements for a fire sprinkler riser rooms must be addressed on the plans prior to any permit approval. The sprinkler riser room shall be separated from the building on all sides by a one-hour Occupancy Separation assembly, including opening and penetration protection, as defined by the Building Code. In addition to any other access doors, direct access into the riser room from the outside shall be provided. Signs identifying doors leading to the sprinkler system control assembly shall be permanently affixed to all doors so as to clearly identify the path to the riser assembly. Since no outside control is being provided, address this requirement on the plan/s. (BMC 7-01-53, 903.1.3)

5. Provide depth of cover which shall be measured from the top of pipe to finish grade throughout. (NFPA 13-10.4, 24-10.4)

6. Item #3 on the riser detail, clearance requirement for 6" is 4" clearance. Reference 13-9.3.4.2 and Item #25 below.

NOTE: Read through the rest of this review and it may help the process if the related items were included on the plan/s.
Telephone call  3/15/2006  
Informed Elisha (DeBest Fire Protection) ###-#### to pick up failed permit 3-15-06 eus
Telephone call  3/15/2006 DONE
plans failed customer picked up
Application received  3/13/2006