Permit Information
Permit NumberFIR06-00495
StatusFinaled
Name MOUNTAIN ALARM
Site Address 412 S 13TH ST
Project Namealm Plaza Mixed Use-Pkg Garage
Customer Number 
ePlanReview 
Description
New sprinkler monitoring and notification system
27 system and 130 standalone residential smoke detector Initiating Devices
Scope: To provide AFS monitoring, occupant notification and elevator recall for a 42 unit multi-family complex with interior corridors. The associated building permit is BLD 05-02204.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection7/16/20077/16/20077/17/2007PPASS
DetailsForrest France
Fire alarm permit finaled.
INSP-Final Inspection5/1/20075/1/20075/1/2007PFAIL
DetailsForrest France
Tamper switch at the first floor control valve still does not function, weatherproof covers at the 5th floor outdoor notification devices are not yet installed, provide map at the panel as discussed.
INSP-Alarm Testing5/1/20075/1/20075/1/2007 PART
Approved for TOC. Need final Test Certificate.
INSP-Final Inspection4/27/20074/30/20074/30/2007APART
DetailsForrest France
Remainder of fire alarm system testing completed today, need to provide map at the panel, provide weatherproof protection for the outdoor 5th floor notification devices, repair and retest first floor fire sprinkler tamper switch.
INSP-Final Inspection4/26/20074/27/20074/27/2007APART
DetailsForrest France
Tested previously noted correction items at unit 210 and 312. Open horn circut #3 on the panel at time of inspection due to contractor in process of repair for temporal pattern at the 5th floor notification devices, final pending completion of this issue and satisfactory test of the remaining alarm work.
INSP-Final Inspection4/25/20074/26/20074/26/2007APART
DetailsForrest France
Tested 120V smoke alarms for the dwelling units on the 5th, 4th, 3rd and 2nd floors, noted one device to be moved in unit 210, one device repaired while on site 3rd floor, no access to unit 312, verified signals recieved and corrected descriptor for the waterflow alarms.
INSP-Final Inspection4/24/20074/25/20074/25/2007APART
DetailsForrest France
AFS monitoring, FACP, nac panels, first floor notification, detection and initiation tested today. Noted items in need of correction including correct size batteries at the main panel, dB level in the trash chute rooms, the mini horns in the residential units do not produce the required temporal pattern per review notes or NFPA 72, no elevator devices tested at this time, list of signals recieved to be verified at next scheduled inspection.
Alarm Plan Check4/23/2007 4/23/2007 PASS
Fire Alarm Plan Modification 2nd Review
PLANS/APPL TAKEN TO FRONT DESK  4/23/2007  
Ready for Issue
Permit Ready to Issue  4/23/2007 DONE
Telephone call  4/23/2007 DONE
call to lynde, permit ready to p/u and no fee, left msg on vm
Inspection Record Card- Fire4/23/2007 4/23/2007 DONE
(F) Reprint permit  4/23/2007 DONE
CHANGE STATUS TO (ISS)  4/23/2007 DONE
Plan resubmittals received  4/20/2007  
PLan Mod per Mike Timmerman
Plan assigned to (Mike)4/20/2007 4/20/2007 DONE
FIR-Aging Inspection2/22/20072/22/20072/23/2007 DONE
DetailsForrest France
Project is still under construction.
Plan assigned to (SAM)7/7/2006 10/9/2006 PASS
10/9/2006 10:30:14 MWT - activity updated through activity FIRA22 from case FIR06-00639.
Issue and Print Permit  8/7/2006 DONE
Alarm Plan Check  7/31/2006 PASS
Approved by FV on 7/16/06; held up by MF due to plan deficiencies; approved to issue based on discussion with FV 7/28/06.
PLANS/APPL TAKEN TO FRONT DESK  7/31/2006 DONE
Permit Ready to Issue  7/31/2006 DONE
Inspection Record Card- Fire7/31/2006 7/31/2006 DONE
Telephone call  7/31/2006 DONE
spoke to darcy@###-####/told permit was ready, permit#, project name & address and fee
Miscellaneous action  7/11/2006  
Sent to Floyd Varley.
Application received  7/7/2006  
Case Summary  7/7/2006 DONE
Case Summary  7/7/2006 DONE