Permit Information
Permit NumberFIR07-00145
StatusFinaled
Name SHILO AUTOMATIC SPRINKLER CO
Site Address 1112 W MAIN ST Unit: 503
Project NameROYAL PLAZA
Customer Number 
ePlanReview 
Description
This TI in suite #503 includes dropping 25 residential heads into the new wall and ceiling layout of the dwelling unit and 3 other Dry SSP heads on the terrace. The work shall be performed in accordance with NFPA13R installation guidelines. This building is fully fire sprinklered for one-hour substitution. The fire sprinkler system work shall comply with IFC 2003, attached review comment and conditions list, as regulated by the Fire Chief. These notes, permit and fire "Inspection Card" are required to be on site as a condition of this work, to provide witness of compliance verification of minimum code. This permit is attached to BLD6-03520.
When tenant work affects fire sprinkler protection outside the permitted work area due to the installation of tenant-demising or new partition walls, the affected area sprinkler coverage outside the BLD permit will fall under the Fire Permit scope of work, to maintain the required fire protection within the fire sprinklered facility. The “Riser” and its supplies which include all appurtenances (including tamper, alarm and alarm monitoring) relating to the normal and correct function and integrity of this system will fall under the jurisdiction for code compliant verification.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection1/9/20081/10/20081/10/2008PPASS
DetailsForrest France
Fire sprinkler permit finaled.
INSP-Sprinkler Rough-in/Hydro10/25/200710/26/200710/29/2007PPART
DetailsForrest France
Hydro test passed.
INSP-Final Inspection8/22/20078/23/20078/23/2007AFAIL
DetailsForrest France
Missing sprinkler protection at one closet which exceeds dimentions allowed for coverage omission, remainder of ceilings are okay for cover.
INSP-Sprinkler Rough-in8/16/20078/17/20078/17/2007ANR
DetailsForrest France
Pending light fixture obstruction issues.
Permit Ready to Issue  5/31/2007 DONE
Telephone call  5/31/2007 DONE
tlk to lilly at shilo ###-#### that permit and fees are ready to be picked up
Issue and Print Permit  5/31/2007 DONE
Meeting  5/30/2007 DONE
Meeting with Rita Deyong regarding status of attached Buidling permit, and when to issue these permits. I gave approval to issue the permit, due to the excessive length of time it is taking to get the Building plans reviewed. If there are descrepancied between the final approved building plans and those used by the sprinkler designer, it will be the responsibility of the sprinkler contractor to resubmit modified plans or if approved by the inspector, to have "as builts" on site at time of inspection.
Sprinkler Plan Check2/15/2007 3/1/2007 PASS
plans are approved as submitted by bryan johnson
note: bld. permit is being reviewed, unable to issue this permit unith the bld. permit has been issued
Inspection Record Card- Fire2/28/2007 2/28/2007 DONE
Application received  2/15/2007  
Pending Assignment by SAM2/15/2007