Permit Information
Permit NumberFIR07-00676
StatusFinaled
Name LEA ELECTRIC LLC
Site Address 1112 W MAIN ST Unit: 1ST FLR
Project NameROYAL PLAZA
Customer Number 
ePlanReview 
Description
This fire alarm permit is to construct and complete the 1st floor corridor in the Royal Plaza building. This permit does not allow occupancy. The building fire alarm system includes, but is not limited to a required manual and automatic fire alarm system to include fire alarm initiating devices, notification appliances, fire command center, voice evacuation, fire fighter communications (phones), fire sprinkler and fire pump monitoring, HVAC duct smoke detectors, in-duct smoke detection, fire smoke dampers, elevator recall, shunt trip and offsite reporting. Building Permit # BLD07-01082 is to construct a 785 square foot entrance/elevator/stairway lobby on the 1st story of a high-rise building to serve the dwelling units located on the upper stories. In addition, to construct a 497 square foot corridor on the 1st story to connect the new lobby to an existing 2-hr stairway exit passageway. The corridor will likely serve as a secondary means of egress from future retail sales tenants. Work is to include 1-hr walls, 20 minute doors, suspended gypsum board ceilings, suspended acoustical ceilings, and finishes. The lobby and corridor are NOT required to be fire-resistance-rated enclosures by the building code. The construction proposed will exceed the requirements of the code. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes. The fire sprinkler system is required to comply with NFPA 13 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection12/7/200712/7/200712/7/2007PPASS
DetailsForrest France
Fire alarm permit finaled.
INSP-Alarm Testing12/6/200712/6/200712/6/2007PPASS
DetailsForrest France
Corrections verified for completion, fire alarm testing passed.
INSP-Final Inspection12/5/200712/5/200712/5/2007PFAIL
DetailsForrest France
Still need items 1, and 3-5 on correction notice completed prior to permit final.
INSP-Conference10/16/200710/18/200710/18/2007ADONE
DetailsTroy Cobbley
Mike timmereman performed conference.
Issue and Print Permit  8/15/2007 DONE
Plan assigned to (Mike)8/3/2007 8/14/2007 PASS
8/14/2007 10:22:09 MWT - activity updated through activity FIRA22 from case FIR07-00676.
Alarm Plan Check8/14/2007 8/14/2007 PASS
Fire Alarm Review 1st
PLANS/APPL TAKEN TO FRONT DESK  8/14/2007  
Ready for Issue
Telephone call  8/14/2007  
lft vm with rob ahten that permit and fees are ready to be picked up
Inspection Record Card- Fire8/14/2007 8/14/2007 DONE
Permit Ready to Issue  8/14/2007 DONE
Application received  8/3/2007