Information based on query as of Saturday, August 17, 2024.
Permit Information
Permit NumberFIR08-00858
StatusFinaled
Name ABSOLUTE FIRE PROTECTION
Site Address 3501 W ELDER ST
Project NameUNA MAS BLDG
Customer Number 
ePlanReview 
Description
The Fire Sprinkler Scope of work consists of relocating and adding new heads to accommodate new wall and ceilings configurations.

(ASSURANT HEALTH) New 10,203 sq. ft. office space in an existing vacant shell space on the third floor of a 3 story building, with basement per approved plans. NOTE: This building is fully fire sprinklered for one-hour substitution. Work includes installation of interior non-bearing walls to create (13) private offices, (2) open office areas, (1) conference room, (1) Training room, (1) Breakroom, (1) File/Copy room, Millwork, installation of a suspended ceiling grid system, and miscelanous finishes. Work also includes HVAC, Plumbing and Electrical. Common core restrooms & drinking fountains are located on each level W/ common service sink on third level, all part of Shell /Core permit (BLD06-00688). There is an existing central core to this building, approximately 780 sq. ft., which includes the three exit stair systems; and an elevator for accessibility compliance. Any modifications to the fire sprinkler system is required to comply with NFPA 13 as regulated by the Fire Department. All work per the approved plans, Engineering, and Plan Review report. **SRZ**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection3/23/20093/24/20093/24/2009APASS
DetailsForrest France
C/N items repaired, fire sprinkler permit finaled.
INSP-Sprinkler Rough-in3/5/20093/5/20093/5/2009PPART
DetailsForrest France
Okay to cover with exceptions noted at the file/copy room and the breakroom, including overspaced heads at the breakroom and one additonal head required at the file room, also noted one existing ssu at the deck to be removed, see plans for locations.
Issue and Print Permit  1/6/2009 DONE
Sprinkler Plan Check1/2/2009 1/2/2009 PASS
DetailsTim Frost
No Comments, See attached
There are NO annotations on the plans.
PLANS/APPL TAKEN TO FRONT DESK  1/2/2009 DONE
Inspection Record Card- Fire1/2/2009 1/2/2009 DONE
DetailsCathy Brown
Telephone call  1/2/2009 DONE
DetailsCathy Brown
tlk to absolute fire ###-#### that permit and fees are ready to be picked up
Permit Ready to Issue  1/2/2009 DONE
DetailsCathy Brown
Application received  12/29/2008  
Case Summary  12/29/2008 DONE