Permit Information
Permit NumberFIR09-00226
StatusFinaled
Name TRI STATE ELECTRIC
Site Address 851 W FRONT ST Unit: 1702
Project NameTHE ASPEN - UNIT 1702
Customer Number 
ePlanReview 
Description
This fire alarm permit is to provide speakers, speaker/strobes, and single/multi-station smoke alarms as a tenant improvement for a condo. These devices are an extension of the building voice evacuation system.

Associated building permit: BLD08-01714 (THE ASPEN - RESIDENTIAL UNIT 1702) Fire sprinklers required because this building is a high-rise. To create a 2,310 square foot dwelling unit on the 17th story and 18th story of a new high-rise building (1,046 square feet on the 17th story and 1,264 square feet on the 18th story). The 1-hr corridor/lobby on the 17th story will be constructed in conjunction with this permit. Work is to include 1-hr fire-resistance-rated tenant demising walls, 1-hr fire-resistance-rated corridor, interior nonbearing walls, suspended gypsum board ceilings, a noncombustible open stairway, guard, millwork, and finishes. The portion of this dwelling unit located on the 17th story is required to comply with ICC/ANSI A117.1-2003 Section 1004 as a Type B dwelling unit. The portion of this dwelling unit located on the 18th story is not regulated for accessibility. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  10/1/2009 DONE
Fire alarm plans taken to records for scanning
INSP-Final Inspection9/29/20099/29/20099/29/2009PPASS
DetailsForrest France
Fire alarm testing passed, permit finaled.
INSP-Final Inspection9/15/20099/21/20099/22/2009AFAIL
DetailsForrest France
Smoke alarms must be interconnected per IFC requirements- see fire code review note #29. Notification tested okay.
Issue and Print Permit  9/9/2009 DONE
Miscellaneous action  5/1/2009 DONE
roll of plans went out on site with issuance of Fir09-00208//ok per SLC
Plan assigned to (Stephanie)4/7/2009 4/22/2009 DONE
DetailsStephanie L. Cobbley
4/22/2009 08:18:33 SLC - activity updated through activity FIRA24 from case FIR09-00226.
Inspection Record Card- Fire4/22/2009 4/22/2009 DONE
Details
Telephone call  4/22/2009 DONE
Details
t/c w phil at ###-#### - permit ready and fees given
Permit Ready to Issue  4/22/2009 DONE
Details
Alarm Plan Check4/21/2009 4/21/2009 PASS
DetailsStephanie L. Cobbley
See review comments
PLANS TAKEN FRONT DESK ALARM  4/21/2009 DONE
Approved plans available at front counter
Application received  4/7/2009