Permit Information
Permit NumberFIR09-00522
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 10396 W OVERLAND RD
Project NameFIVE MILE PLAZA
Customer Number 
ePlanReview 
Description
The Fire Sprinkler Scope of work consists of adding and relocating sprinklers to accommodate new wall and ceiling configurations.

(GREAT WALL RESTAURANT - EXPANSION) This building is fire sprinklered for building area increase. To expand an existing 5,360 square foot restaurant into an adjacent 2,420 square foot area. After the expansion, the tenant space will have a total floor area of about 7,780 square feet. Work is to include a single user restroom accessible to the disabled, interior nonbearing walls, openings in existing nonbearing walls, suspended acoustical ceiling grid, ceiling tiles, millwork, and finishes. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 as regulated by the Fire Department. This space has existing 2-hour rated fire walls on the West and East sides of the space. Fire walls were completed under permit BLD06-03074. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  1/6/2010 DONE
DetailsTim Frost
Taken to scanning
INSP-Final Inspection11/16/200911/17/200911/17/2009APASS
DetailsTroy Cobbley
Permit finaled. I told the owner that a ceiling can not be installed in the small room next to the cooler or a sprinkler pendant will be required. He stated he understood.
INSP-Sprinkler Rough-in9/9/20099/9/20099/9/2009PPART
DetailsForrest France
Overhead fire sprinkler modifications at the remodel area are approved for cover.
Plan assigned to (Tim)9/1/2009 9/2/2009 DONE
DetailsTim Frost
9/2/2009 09:57:26 TRF - activity updated through activity FIRA22 from case FIR09-00522.
Sprinkler Plan Check9/2/2009 9/2/2009 PASS
DetailsTim Frost
Please, see attached comments.
There are NO annotations on the plans.
1st review completed  9/2/2009 DONE
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  9/2/2009 DONE
DetailsTim Frost
Inspection Record Card- Fire9/2/2009 9/2/2009 DONE
Details
Telephone call  9/2/2009 DONE
Details
t/c w jeff anderson at ###-#### - permit ready and fees given
Permit Ready to Issue  9/2/2009 DONE
Details
Issue and Print Permit  9/2/2009 DONE
Application received  9/1/2009