Permit NumberFIR09-00571
StatusFinaled
Name CURTIS FIRE SPRINKLER SERVICE INC
Site Address 408 N GARDEN ST
Project NameCommunity of Christ Church
Customer Number 
ePlanReview 
Description
Quick Permit
Add one head in the bottom of an elevator shaft and relocate one head for a new wall.
(COMMUNITY OF CHRIST CHURCH - ACCESSIBLE LIFT & RAMP) The basement is sprinklered. To provide an accessible route within the existing church improving access to the basement. Work includes select interior demolition; construct a new 1-hour shaft, bearing wall enclosure around a new accessible platform lift between the basement and first floor; relocate existing 20 minute fire/smoke rated door within a new portion of the relocated one hour corridor wall to separate the rated corridor from a new accessible landing and ramp with stairs off one side of the landing; build a half wall along one side of the ramp and add handrails at new stairs and ramp; doors to platform lift that open into the existing corridor on both levels are to be a minimum 20 minute fire & smoke rated assembly. All per reviewed plans, red-line notes and attached plan review comments / conditions. Modification of the existing sprinkler system requires a separate permit and to maintain compliance with NFPA 13, all as regulated by the fire department. drs(COMMUNITY OF CHRIST CHURCH - ACCESSIBLE LIFT & RAMP) The basement is sprinklered. To provide an accessible route within the existing church improving access to the basement. Work includes select interior demolition; construct a new 1-hour shaft, bearing wall enclosure around a new accessible platform lift between the basement and first floor; relocate existing 20 minute fire/smoke rated door within a new portion of the relocated one hour corridor wall to separate the rated corridor from a new accessible landing and ramp with stairs off one side of the landing; build a half wall along one side of the ramp and add handrails at new stairs and ramp; doors to platform lift that open into the existing corridor on both levels are to be a minimum 20 minute fire & smoke rated assembly. All per reviewed plans, red-line notes and attached plan review comments / conditions. Modification of the existing sprinkler system requires a separate permit and to maintain compliance with NFPA 13, all as regulated by the fire department. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection11/10/200911/10/200911/10/2009PPASS
DetailsTroy Cobbley
Permit finaled
INSP-Sprinkler Rough-in9/21/20099/21/20099/21/2009PPASS
DetailsTroy Cobbley
The sprinkler piping is ok to cover.
Issue and Print Permit  9/21/2009 DONE
Sprinkler Plan Check9/17/2009 9/17/2009 PASS
DetailsTim Frost
Please, see attached comments.
There are NO annotations on the plans.
PLANS/APPL TAKEN TO FRONT DESK  9/17/2009 DONE
DetailsTim Frost
1st review completed  9/17/2009 DONE
DetailsTim Frost
Inspection Record Card- Fire9/17/2009 9/17/2009 DONE
Details
Telephone call  9/17/2009 DONE
Details
t/c w don curtis at ###-#### - permit ready and fees given
Permit Ready to Issue  9/17/2009 DONE
Details
Application received  9/16/2009  
Pending Assignment by SAM9/16/2009