Permit Information
Permit NumberFIR09-00608
StatusFinaled
Name SNAKE RIVER ELECTRIC INC
Site Address 2822 S VISTA AVE
Project NamePacific Cataract & Laser Insti
Customer Number 
ePlanReview 
Description
This fire alarm permit is to provide a new fire alarm panel for sprinkler system and HVAC monitoring. Also included in this permit scope are a non-required manual system and a non-required partial coverage automatic detection system. By providing the manual and automatic detection systems, full notification coverage is required.

Associated building permit: BLD09-00287 Pacific Cataract & Laser Institute - To construct a new 9,365 square foot, one story with 1,285 square foot mechanical mezzanine, wood framed medical office building (outpatient eye clinic) and related site improvements. This building is fully fire sprinkled. All construction per the approved plans and attached comment list. JCM
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  2/26/2010 DONE
fire alarm plans taken to records for scanning
INSP-Final Inspection2/10/20102/10/20102/10/2010PPASS
DetailsForrest France
Fire alarm permit final approved.
INSP-Final Inspection2/9/20102/9/20102/9/2010PPART
DetailsForrest France
Correction notice items verified for completion, remainder of alarm work passed site testing. Final pending offsite monitoring check via permit FIR09-00740. Contractor to provide missing signage at the door to the FACP room.
INSP-Final Inspection2/5/20102/5/20102/9/2010PNR
DetailsForrest France
Pending modifications per previous inspection- not ready 2/5 per phone call from contractor.
INSP-Final Inspection2/4/20102/4/20102/4/2010PFAIL
DetailsForrest France
Smoke detectors at three locations are too close to HVAC diffusers, missing one SD address D1-13, HVAC units must shut down immediately upon duct smoke activation. Fire sprinkler riser supervision tested okay, five MP stations, battery trouble, open circuts, and notification circuts all passed functional testing. Offsite monitoring to be verified under project related FIR permit inspection. Plan resubmittals verified.
Plan assigned to (Stephanie)1/29/2010 2/3/2010 DONE
DetailsStephanie L. Cobbley
2/3/2010 11:50:07 SLC - activity updated through activity FIRA24 from case FIR09-00608.
Plan resubmittals received  2/3/2010  
DetailsTisha Gallop
supplemental plans: received two copies of battery calcs, plan sheet E3.0 and riser diagram; taken to fire review
Alarm Plan Check2/3/2010 2/3/2010 PASS
DetailsStephanie L. Cobbley
plan modification approved
PLANS TAKEN FRONT DESK ALARM  2/3/2010 DONE
plan modification approved plans available at front counter
Inspection Record Card- Fire2/3/2010 2/3/2010 DONE
Details
Telephone call  2/3/2010 DONE
Details
t/c w stu at ###-#### - permit (plan mod) ready and fees given
Permit Ready to Issue  2/3/2010 DONE
Details
Issue and Print Permit  2/3/2010 DONE
Plan resubmittals received  1/29/2010  
DetailsTisha Gallop
Plan modification: Received two copies of application, submittal folder and plan sheets E3.0, E4.0, (no number sheet); taken to Fire Review.
Issue and Print Permit  11/17/2009 DONE
Inspection Record Card- Fire11/3/2009 11/3/2009 DONE
Details
Telephone call  11/3/2009 DONE
Details
t/c w stu at ###-#### - permit ready and fees given
Permit Ready to Issue  11/3/2009 DONE
Details
Plan assigned to (Stephanie)10/15/2009 11/2/2009 DONE
DetailsStephanie L. Cobbley
11/2/2009 15:53:55 SLC - activity updated through activity FIRA24 from case FIR09-00608.
Telephone call  11/2/2009 DONE
Spoke with Rob Ahten and let him know there were still several deficiencies in the plans, however, I gave him the option of me rejecting the plans now so he can correct the issues and only pay one review fee or I could approve them as-noted with the understanding he would need to resubmit a plan modification prior to calling for a final inspection, thus paying an additional review fee. He opted for getting the plans approved with noted now and submitting a plan modification prior to calling for a final inspection.
Alarm Plan Check11/2/2009 11/2/2009 PASS
DetailsStephanie L. Cobbley
A plan modification will need to be submitted implementing all notes, corrections, and field modifications prior to calling for a final inspection.
PLANS TAKEN FRONT DESK ALARM  11/2/2009 DONE
Approved redlined plans available at front counter.
Plan resubmittals received  10/29/2009  
DetailsTisha Gallop
received two copies of application, submittal docs, and plan sheets E3.0, E4.0, and 1 sheet no pg#. Taken to Fire Review.
1st review completed  10/21/2009 DONE
Alarm Plan Check10/21/2009 10/21/2009 FAIL
DetailsStephanie L. Cobbley
see redlined plans and review comments
Miscellaneous action  10/21/2009 DONE
Faxed comments to Protex at their request. Tried to fax comments to the installing contractor but the number provided is not a valid number. Will try to call the phone number provided to let them know the plans have been failed.
Telephone call  10/21/2009 DONE
Left a message for Stu Welton at Snake River Electric letting him know the plans have been denied and that the fax number provided was not a valid number. I let him know that the review comments are available on the city website, but if he had any additional questions to feel free to give me a call. I then left my contact information.
Miscellaneous action  10/21/2009 DONE
DetailsTisha Gallop
picked up rejected plans
Application received  10/15/2009