Description
This fire alarm permit is to provide a new sprinkler monitoring system in an existing building due to a tenant improvement. Notification is not part of this permit scope. HVAC functions were not indicated, therefore will require a re-submittal or separate permit if duct detectors are required/installed. An upgrade agreement exists for this address but does not appear to have any impact on the fire alarm at this time. For further details, see the upgrade agreement document attached to BLD09-02253.

Associated building permit: BLD09-02253 (FARMERS BROTHERS COFFEE) Permit is to remodel an existing 8,032 square foot office / warehouse building. UPGRADE AGREEMENT APPROVED FOR THIS BUILDING - agreement is attached to this case. Approval contingent upon adhering to the approved plans on file, attached engineering, and CZC09-00222. Work to include: [construction of interior non-bearing walls to create two fully accessible bathrooms, a new managers office, a fire sprinkler riser room, and to isolate off common area], installation of new accessible bathroom fixtures, installation of new hand sink, installation of new exterior landing, installation of new exterior loading ramp, installation of new opening in tilt-up wall, and finishes in compliance with chapter 8 of the 2006 IBC. This building is to be fully fire sprinklered per NFPA #13 as regulated by the fire department to comply with area requirements. Racking that exceeds 8 ft. in height requires a separate Building Permit be submitted and approved before installation (Racking permit # BLD09-02212). UPGRADE AGREEMENT APPROVED FOR THIS BUILDING - agreement is attached to this case. **TLW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  4/16/2010 DONE
Plans taken to records for scanning.
INSP-Final Inspection3/17/20103/19/20103/19/2010APASS
DetailsForrest France
Correction items revised, re-testing completed acceptable, as-builts recieved, fire alarm permit finaled.
INSP-Final Inspection3/18/20103/18/20103/18/2010PFAIL
DetailsTroy Cobbley
Trouble signals did not annuciate at the facp as required, battery was not a 8ah, as-builts reflecting the additional flow switch and the two additional tamper switches. Also the order in which the devices were tested was not reflected in the order that the central station received them. Electrician was going to provide the lock for the dedicated circuit. I let Doug know that signage would be required for the riser room/facp room door.
Issue and Print Permit  2/8/2010  
Plan assigned to (Stephanie)2/2/2010 2/5/2010 DONE
DetailsStephanie L. Cobbley
2/5/2010 11:32:53 SLC - activity updated through activity FIRA24 from case FIR10-00049.
1st review completed  2/5/2010 DONE
Alarm Plan Check2/5/2010 2/5/2010 PASS
DetailsStephanie L. Cobbley
Plans approved - see redlines and review comments
PLANS TAKEN FRONT DESK ALARM  2/5/2010 DONE
approved redlined plans available at front counter
Inspection Record Card- Fire2/5/2010 2/5/2010 DONE
Details
Permit Ready to Issue  2/5/2010 DONE
Details
Telephone call  2/5/2010 DONE
Details
left vm for bret at ###-#### - permit ready and fees given
Application received  2/2/2010