Permit Information
Permit NumberFIR10-00105
StatusFinaled
Name ALARMCO
Site Address 10005 W PATTIE DR
Project NamePATTIE HOUSE REMODEL
Customer Number 
ePlanReview 
Description
This quick permit is to modify the existing fire alarm system to add notification and a smoke detector to a new bedroom. Also part of this permit scope is to add notification to a hall that was created when the garage was split to add the bedroom. Approval is subject to field measurement of the EOL voltage drop. The voltage drop calculations are based on a 10% drop, therefore the minimum acceptable voltage is 21.6V with the AC power off. Any measurement below this voltage will be considered insufficient to run the NACs at the end of useful battery life of 20.4V. UL 864, Standard for Control Units for Fire Signaling Systems. There are no written review comments. Assocated building permit: BLD10-00330 This project is for the addition of 410s.f. of living space in an existing single family by converting the 2-bay portion of the garage area, This will leave a single bay drive through garage with a parking pad behind. There will be 40l.f. of interior non bearing partition placed in this area, one to create a bedroom / sitting room divider and the other to enclose the garage door area. One egress window is required to be installed. R-1C ok per Colleen Carroll. This dwelling is used as an R-4 residential care / assisted living with R-3 requirements per Boise City Building Division Policy R310.1 R-4 3-20-2008 by the building official, George Slane. Separate electrical permit is required. All per the approved plans as marked REScheck and the plan review notes. pep
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  4/16/2010 DONE
Plans taken to records for scanning.
INSP-Final Inspection3/15/20103/16/20103/16/2010APASS
DetailsTroy Cobbley
Permit finaled. Eol voltage was verified. Zone 1 and Zone 2 were switched. As-builts to be picked up at contractors office by me.
Issue and Print Permit  3/15/2010 DONE
Plan assigned to (Stephanie)3/11/2010 3/12/2010 DONE
DetailsStephanie L. Cobbley
3/12/2010 11:23:31 SLC - activity updated through activity FIRA24 from case FIR10-00105.
Plan assigned to (Stephanie)3/11/2010 3/12/2010 DONE
DetailsStephanie L. Cobbley
3/12/2010 11:23:31 SLC - activity updated through activity FIRA24 from case FIR10-00105.
1st review completed  3/12/2010 DONE
Alarm Plan Check3/12/2010 3/12/2010 PASS
DetailsStephanie L. Cobbley
Quick permit approved - no written review comments
PLANS TAKEN FRONT DESK ALARM  3/12/2010 DONE
Approved plans available at front counter
Inspection Record Card- Fire3/12/2010 3/12/2010 DONE
Details
Telephone call  3/12/2010 DONE
Details
t/c w lori at ###-#### - permit ready and fees given
Permit Ready to Issue  3/12/2010 DONE
Details
Application received  3/11/2010