Permit Information
Permit NumberFIR10-00110
StatusFinaled
Name FOCUS MICRO INC
Site Address 909 E PARKCENTER BLVD
Project NameUS Bank Albertson's #169
Customer Number 
ePlanReview 
Description
This quick permit is to relocate two existing ceiling mounted hornstrobes due to a tenant remodel. No battery calcs or voltage drops necessary. No written comments. Associated building permit: BLD10-00103 (US Bank) For tenant improvements to an existing 329 sq. ft tenant space within an existing 50,724 sq. ft. Albertsons store with work to include the instaallation of approximately 45 lineal feet of interior non-bearing partition wall, installation of a new ATM, new lighting, millwork HVAC including a condensing unit and related ducting, and related interior finishes. All wotk to be done per the approved plans and all applicable codes. This is a fully sprinklered building:any alterations to the sprinkler system will require a separate permit and shall comply with NFPA13 as regulated by the City of Boise Fire Department. CDM
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  4/16/2010 DONE
Plans taken to records for scanning.
INSP-Final Inspection3/19/20103/19/20103/19/2010PPASS
DetailsForrest France
Fire alarm permit approved for final status.
INSP-Alarm Testing3/18/20103/19/20103/19/2010APASS
DetailsForrest France
Fire alarm work passed field testing.
Issue and Print Permit  3/18/2010 DONE
Plan assigned to (Stephanie)3/15/2010 3/17/2010 DONE
DetailsStephanie L. Cobbley
3/17/2010 07:34:35 SLC - activity updated through activity FIRA24 from case FIR10-00110.
Plan assigned to (Stephanie)3/16/2010 3/17/2010 DONE
DetailsStephanie L. Cobbley
3/17/2010 07:34:35 SLC - activity updated through activity FIRA24 from case FIR10-00110.
Alarm Plan Check3/17/2010 3/17/2010 PASS
DetailsStephanie L. Cobbley
Quick permit approved - no written comments
PLANS TAKEN FRONT DESK ALARM  3/17/2010 DONE
Approved plans available at front counter
Inspection Record Card- Fire3/17/2010 3/17/2010 DONE
Details
Telephone call  3/17/2010 DONE
Details
t/c w clint at ###-#### - permit ready and fees given
Permit Ready to Issue  3/17/2010 DONE
Details
1st review completed  3/16/2010 DONE
Alarm Plan Check3/16/2010 3/16/2010 FAIL
DetailsStephanie L. Cobbley
Telephone call  3/16/2010 DONE
Spoke to Clint and explained I would need to deny the plans due to insufficient information to complete the review. I went over the following: The drawings are not 1/8" scale, I could not verify the spacing requirements for the notification has been met, the candela of the devices are not shown, devices are shown in areas that do not require notification and are not shown in areas that do require notification, the name of the designer and his/her qualification are not shown, etc.. He understood he would need to provide the information in the form of a resubmittal. I asked if he needed me to fax him anything formal indicating a resubmittal is required, and he stated he did not need anything further from me.
Plan resubmittals received  3/16/2010 DONE
Application received  3/15/2010