Miscellaneous action | | | 7/19/2010 | | DONE |
|
|
|
Sent to records for scanning.
|
INSP-Final Inspection | 5/18/2010 | 5/19/2010 | 5/19/2010 | P | PASS |
Troy Cobbley
|
|
|
Permit finaled
|
INSP-Sprinkler Rough-in | 5/3/2010 | 5/4/2010 | 5/4/2010 | A | PASS |
Troy Cobbley
|
|
|
Permit finaled
|
Plan assigned to (Tim) | 4/30/2010 | | 5/3/2010 | | DONE |
Tim Frost
|
|
|
5/3/2010 09:16:51 TRF - activity updated through activity FIRA22 from case FIR10-00148.
|
Sprinkler Plan Check | 5/3/2010 | | 5/3/2010 | | PASS |
Tim Frost
|
|
|
Please, see attached comments.
There are NO annotations on the plans.
|
1st review completed | | | 5/3/2010 | | DONE |
Tim Frost
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/3/2010 | | DONE |
Tim Frost
|
|
|
|
Permit Ready to Issue | | | 5/3/2010 | | DONE |
Barbara Stitt
|
|
|
|
Inspection Record Card- Fire | 5/3/2010 | | 5/3/2010 | | DONE |
Barbara Stitt
|
|
|
|
Telephone call | | | 5/3/2010 | | DONE |
Barbara Stitt
|
|
|
Called Phoenix Fire Protection and told them permit is ready & fees @ 11:10am on 5-3-10 BAS
|
Issue and Print Permit | | | 5/3/2010 | | DONE |
|
|
|
|
Plan resubmittals received | | | 4/30/2010 | | DONE |
Tisha Gallop
|
|
|
Plan Modification: Received three copies of application, submittal documents and plan sheet 1 of 1; taken to fire review
|
INSP-Final Inspection | 4/23/2010 | 4/23/2010 | 4/26/2010 | P | FAIL |
Troy Cobbley
|
|
|
Scott Phone #: ###-####. Inspection was for a rough to cover not a final inspection. Plan Mod required. Sprinkler spacing has been changed to 130 sf instead of the submitted 120 sf. The number of sprinklers on the branch lines changed. The pipe sizing was different from the approved plans. Hydraulics will be required to verify new spacing.
|
Issue and Print Permit | | | 4/15/2010 | | |
|
|
|
|
Sprinkler Plan Check | 4/14/2010 | | 4/14/2010 | | PASS |
Tim Frost
|
|
|
Please, see attached comments.
There are NO annotations on the plans.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 4/14/2010 | | DONE |
Tim Frost
|
|
|
|
Telephone call | | | 4/14/2010 | | DONE |
|
|
|
t/c w michelle at ###-#### - permit ready and fees given
|
Inspection Record Card- Fire | 4/14/2010 | | 4/14/2010 | | DONE |
Patricia Smith
|
|
|
|
Permit Ready to Issue | | | 4/14/2010 | | DONE |
|
|
|
|
Plan resubmittals received | | | 4/13/2010 | | |
Tisha Gallop
|
|
|
received three copies of application, submittal documents and plan sheet 1 of 1; routed to fire
|
Plan assigned to (Tim) | 4/5/2010 | | 4/8/2010 | | DONE |
Tim Frost
|
|
|
|
Sprinkler Plan Check | 4/8/2010 | | 4/8/2010 | | FAIL |
Tim Frost
|
|
|
Please, see attached comments.
There are NO annotations on the plans.
|
1st review completed | | | 4/8/2010 | | DONE |
Tim Frost
|
|
|
|
Telephone call | | | 4/8/2010 | | |
|
|
|
t/c w michelle at ###-#### - permit denied - needs to be picked up and resubmitted
|
Application received | | | 4/5/2010 | | |
|
|
|
|
Pending Assignment by SAM | 4/5/2010 | | 4/5/2010 | | DONE |
Alexandra L. DeYoung
|
|
|
4/5/2010 15:56:11 ALR - activity updated through activity FIRA158 from case FIR10-00148.
|