Permit Information
Permit NumberFIR10-00189
StatusFinaled
Name TAYLOR BROTHERS FIRE & SAFETY
Site Address 390 E PARKCENTER BLVD Unit: 130
Project NameTherapeutic Associates Inc
Customer Number 
ePlanReview 
Description
The Fire Sprinkler Scope of work consists of adding and relocating 5 sprinklers due to new wall and ceiling configuration. The existing system in this area, is a small 2½"'x2½" x1¼" grid. The area is located in the SW corner of the first floor. The main riser is in the NW corner. The existing water supply is reported as S-45, R-29, Q-3000. The existing hydraulic most remote area is located on the second floor of a two-floor building and the demand was reported as 319 GPM @ 40 PSI. This equates to a 4.8 cushion, which is approximately 10.7% below the available water supply. The area is a light hazard offices.

(THERAPEUTIC ASSOCIATES, INC - RIVERPOINT CENTER - STE 130) Permit is to remodel an existing 2,819 square foot office space for a new tenant. Approval contingent upon adhering to the approved plans on file. Work to include: demolition of interior non-bearing walls to create additional open office space, installation of new accessible customer service counter, installation of new interior non-bearing walls to create a charting area and an additional office, installation of stacked washer and dryer, and finishes in compliance with chapter 8 of the 2006 IBC. This building is fully fire sprinklered any alterations or modifications to the sprinkler system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA #13 as regulated by the fire department. **TLW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  7/19/2010 DONE
Sent to records for scanning.
INSP-Final Inspection5/3/20105/3/20105/3/2010APASS
DetailsForrest France
Fire life safety final approved.
INSP-Sprinkler Rough-in4/27/20104/28/20104/28/2010PPART
DetailsForrest France
Overhead system modifications are approved for cover at the drop ceilings.
Issue and Print Permit  4/26/2010 DONE
Plan assigned to (Tim)4/22/2010 4/23/2010 DONE
DetailsTim Frost
4/23/2010 10:12:41 TRF - activity updated through activity FIRA22 from case FIR10-00189.
Sprinkler Plan Check4/23/2010 4/23/2010 PASS
DetailsTim Frost
Please, see attached comments.
There are NO annotations on the plans.
1st review completed  4/23/2010 DONE
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  4/23/2010 DONE
DetailsTim Frost
Inspection Record Card- Fire4/23/2010 4/23/2010 DONE
DetailsPatricia Smith
Telephone call  4/23/2010 DONE
t/c w doug at ###-#### - permit ready and fees given
Permit Ready to Issue  4/23/2010 DONE
Details
Application received  4/22/2010