Permit Information
Permit NumberFIR10-00196
StatusFinaled
Name SHILO AUTOMATIC SPRINKLER CO
Site Address 2734 E WINDSONG DR
Project NameBoulder Heights Residence.
Customer Number 
ePlanReview 
Description
The Fire Sprinkler Scope of work consists of a new residential sprinkler per modified NFPA 13D. In addition, to the NFPA 13D requirements one row of sidewall sprinklers separating the garage and the living space is to be provided, all corridors, closets and bathrooms are to be sprinklered. A dedicated 1½" poly pipe without a meter will supply the sprinkler system. The system will utilize CPVC piping. The pendent sprinklers are based upon a spacing of 18'x18'. The sidewall sprinklers are based on a spacing of 14'x14'.

? (reference Bld08-02280 and Bld09-01293)This permit is for the completion of an existing single family dwelling with original construction under Bld08-02280. The structure is a 3742 Sqft. one story single family dwelling with a basement (basement 1153 Sqft., first story 2648 Sqft.) with 448 Sqft of covered patio, 4 bedrooms, 3 1/2 baths and a 1067 Sqft. attached garage per the approved plans, plan review report, attached engineering and any notations. R-1A/DA zoning and setbacks per planning. CDM A modified 13D fire sprinkler system is required; see plan review notes for further details. SLR
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  9/8/2010 DONE
Sent to records for scanning.
INSP-Final Inspection8/9/20108/10/20108/10/2010APASS
DetailsTroy Cobbley
Permit finaled
INSP-Final Inspection8/6/20108/9/20108/9/2010PFAIL
DetailsTroy Cobbley
There is a pendant head located in a basement closet that has been installed under 4" from a wall. I contacted Tim about the garage door in the basement storage room that is obstructing a single pendant head. Tim stated that he was alright with it.
INSP-Sprinkler Rough-in5/13/20105/14/20105/14/2010PDONE
DetailsTroy Cobbley
Rough In Passed. The GC said he would put batt insulation over the piping first,over the visqueen and then the blow insulation.

Raul is the contact. Thanks Inspection requested from web by: Stan Beus Phone #: ###-####
INSP-Sprinkler Rough-in/Hydro5/12/20105/13/20105/13/2010PFAIL
DetailsTroy Cobbley
See the city approved plans for deficiencies that need corrected. This includes overspaced pendants and tenting/insulation issues.
Issue and Print Permit  4/29/2010 DONE
Application received  4/28/2010  
Pending Assignment by SAM4/28/2010 4/28/2010 DONE
DetailsAlexandra L. DeYoung
4/28/2010 14:22:56 ALR - activity updated through activity FIRA158 from case FIR10-00196.
Plan assigned to (Tim)4/28/2010 4/28/2010 DONE
DetailsTim Frost
4/28/2010 15:50:22 TRF - activity updated through activity FIRA22 from case FIR10-00196.
Sprinkler Plan Check4/28/2010 4/28/2010 PASS
DetailsTim Frost
Please, see attached comments.
There are NO annotations on the plans.
1st review completed  4/28/2010 DONE
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  4/28/2010 DONE
DetailsTim Frost
Inspection Record Card- Fire4/28/2010 4/28/2010 DONE
DetailsPatricia Smith
Telephone call  4/28/2010 DONE
left vm for cameron at ###-#### - permit ready and fees given
Permit Ready to Issue  4/28/2010 DONE
Details