Permit Information
Permit NumberFIR10-00402
StatusFinaled
Name ALLIED GENERAL FIRE & SECURITY
Site Address 8233 W FRANKLIN RD
Project NameCAFE RIO-FRANKLIN TOWNE PLAZA
Customer Number 
ePlanReviewNo
Description
This fire alarm permit is to provide a non-required (owner requested) automatic fire alarm system in a partially sprinklered tenant space. The system full area smoke detection, full notification, HVAC shutdown, and heat detectors.

Associated building permit: BLD10-01207 (CAFE RIO - EAST END OF BUILDING) (8-16-10 PLAN MODIFICATION TO CHANGE THE CURP RAMP AND TO CHANGE THE MOUNTING OF THE TRACK FOR THE ROLL-DOWN FIRE DOOR). Partial fire sprinkler system required for fire area occupant load. To remodel an existing 2,580 square foot tenant space and convert it to a restaurant with a kitchen. Work it to include 2 restrooms accessible to the disabled, interior nonbearing walls, four (4) Type I grease hoods, one (1) Type II hood, interior decorative canopies, a suspended decorative log ceiling element, suspended acoustical ceilings, structural work to support new roof top equipment (concrete footings, steel and wood columns, steel and wood beams, etc.), kitchen equipment, a grease trap, and finishes. Transfer blocks and bottom cord sleepers will be added to the existing roof trusses as part of the structural modifications needed to support hoods and new roof top equipment. In addition, a 2-hr fire-resistance-rated fire barrier wall will be constructed to completely separate this building, the canopy included, into two separate fire areas. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire area containing this tenant space is required to be fire sprinklered in conjunction with this permit. The fire sprinkler system is required to comply with NFPA 13 as regulated by the Fire Department. Interior nonstructural demolition was done under permit BLD10-01546. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  9/20/2010 DONE
FA plans taken to records for scanning.
INSP-Final Inspection9/9/20109/10/20109/10/2010APASS
DetailsForrest France
Noted corrections verified for compliance. Fire alarm testing passed, permit finaled.
INSP-Final Inspection9/8/20109/9/20109/9/2010AFAIL
DetailsTroy Cobbley
Still need to test the duct smoke detectors, heat detectors and smoke detectors. A single smoke detector needs to be provided on the south side of the beam and the two smoke detectors in the center of the dining area need to be mounted at the roof deck instead of the bottom chord of the trusses. One strobe needed to have the candella increased due to overspacing. The PIV tamper switch was wired backwards and one other tamper switch had been by-passed. Both were repaired while I waited. The EOL tested ok as well as the sprinkler system devices and the hood suppression system. Signal reports are needed showing todays work.
Plan assigned to (Stephanie)8/18/2010 9/8/2010 DONE
DetailsStephanie L. Cobbley
9/8/2010 11:48:14 SLC - activity updated through activity FIRA24 from case FIR10-00402.
Alarm Plan Check9/8/2010 9/8/2010 PASS
DetailsStephanie L. Cobbley
Resubmittals approved with redlines and review comments
PLANS TAKEN FRONT DESK ALARM  9/8/2010 DONE
Redlined approved resubmittal documents available at front counter
Inspection Record Card- Fire9/8/2010 9/8/2010 DONE
DetailsPatricia Smith
Telephone call  9/8/2010 DONE
left vm for ken at ###-#### - permit ready and fees given
Permit Ready to Issue  9/8/2010 DONE
Details
Issue and Print Permit  9/8/2010 DONE
DetailsTisha Gallop
Early Start  9/3/2010 DONE
An early start request has been approved for this project
Plan resubmittals received  9/1/2010  
DetailsStephanie L. Cobbley
rec'd 2 sets
1st review completed  8/26/2010 DONE
Alarm Plan Check8/26/2010 8/26/2010 FAIL
DetailsStephanie L. Cobbley
Plans denied - see redlines and review comments
Miscellaneous action  8/26/2010 DONE
Faxed denied review comments to contractor
Miscellaneous action  8/26/2010 DONE
Placed denied, redlined plans at front counter for contractor pick up
Application received  8/18/2010