Permit Information
Permit NumberFIR10-00406
StatusFinaled
Name ALARM STAR
Site Address 10464 W GARVERDALE CT
Project NameCENTER FOR SPIRITUAL LIVING
Customer Number 
ePlanReviewNo
Description
This fire alarm permit is to provide a manual fire alarm system for an existing building. This permit scope includes pull stations, full notification, HVAC monitoring/shut down, and sprinkler system monitoring.

Associated building permit: BLD10-00114 (CENTER FOR SPIRITUAL LIVING) This building will be fully fire sprinklered for the occupant load in the fire area. To convert an existing 7,108 square foot office building (B Occupancy) to a church (A-3 Occupancy). Nonstructural work includes 2 restrooms accessible to the disabled, an interior ramp accessible to the disabled, interior nonbearing walls, interior doors, interior windows, exterior windows, and finishes. Structural work includes a new roof structure, bearing walls, beams, columns, headers, shear walls, joists, concrete footings, etc. The work is required to comply with the approved drawings, with the plan review report, with the structural design, and with all applicable codes and standards. The new fire sprinkler system is required to comply with NFPA 13 as regulated by the Fire Department. Interior nonstructural demolition was done under permit BLD10-00038. Planning approvals done under CUP09-00054, DRH09-00208, & DRH09-00281. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  2/9/2011 DONE
Plans taken to records for scanning.
INSP-Final Inspection12/21/201012/22/201012/22/2010PPASS
DetailsTroy Cobbley
Permit finaled
INSP-Alarm Testing12/3/201012/6/201012/6/2010APASS
DetailsTroy Cobbley
Permit finaled
INSP-Alarm Testing12/2/201012/3/201012/3/2010AFAIL
DetailsTroy Cobbley
I found several overspaced visual devices. I also noted that a room shown on the plans as Prayer is now a mens restroom. The a/v in this room appears to provide adequate coverage. With todays schedule I did not have the extra time to waite at the job site while Items were corrected. No testing was performed. Inspection to be rescheduled.
INSP-Alarm Testing12/1/201012/2/201012/2/2010PCANC
DetailsTroy Cobbley
Canceled due to time constraints caused by Micron plan review. Rescheduled for tomorrow morning.
Inspection Record Card- Fire9/2/2010 9/2/2010 DONE
DetailsPatricia Smith
Telephone call  9/2/2010 DONE
t/c w rand at ###-#### - permit ready and fees given
Permit Ready to Issue  9/2/2010 DONE
Details
Issue and Print Permit  9/2/2010 DONE
Plan assigned to (Stephanie)8/18/2010 9/1/2010 DONE
DetailsStephanie L. Cobbley
9/1/2010 15:42:27 SLC - activity updated through activity FIRA24 from case FIR10-00406.
1st review completed  9/1/2010 DONE
Alarm Plan Check9/1/2010 9/1/2010 PASS
DetailsStephanie L. Cobbley
see redlines and review comments
PLANS TAKEN FRONT DESK ALARM  9/1/2010 DONE
approved redlined plans available at front counter
Application received  8/18/2010