Permit Information
Permit NumberFIR10-00447
StatusFinaled
Name DEBEST FIRE PROTECTION
Site Address 2801 E HARD ROCK DR
Project NameGonazalez Residence
Customer Number 
ePlanReviewNo
Description
The Fire Sprinkler Scope of work consists of adding four sprinklers to an exterior home/office building, which is adjacent to a residence. The system will be supplied from the existing modified 13D system. The existing system has a 38 GPM @ 60 PSI pump. The fire protection system is a modified 13D system requiring sprinklers in all rooms. The original home was sprinklered under permit (FIR07-00174)

Building Department Scope:

To construct a new 384s.f. detached structure, accessory to 2799 E Hard Rock Drive that meets the Accessory Dwelling Unit Requirements. A letter from the applicant's geotechnical engineer indicating that the footing sub-grade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Terry Records at 384-3946. There is a fully engineered iron trellis between this new structure and the existing garage. R-1A/DA approved through CAA10-00053 by Josh Johnson. Separate electrical, plumbing, mechanical and ESC permits are required. All per the approved plans as marked Engineering and the engineer's details along with the plan review notes. pep
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  1/14/2011 DONE
Sent to records for scanning.
INSP-Final Inspection12/15/201012/16/201012/16/2010APASS
DetailsForrest France
Final inspection passed, permit finaled.
INSP-Sprinkler Rough-in12/14/201012/14/201012/14/2010PPART
DetailsForrest France
Adjustments underway.
INSP-Final Inspection12/14/201012/14/201012/14/2010PNR
DetailsForrest France
INSP-Final Inspection12/7/201012/9/201012/9/2010AFAIL
DetailsTroy Cobbley
A soffit has been installed against the south wall which is causing an obstruction. The pendant heads will not provide coverage beneath it. This obstruction was not shown on the approved sprinkler plans. Also the flow switch needs to be tested through an approved orfice. The approved plans show a bell on the new office but one has not been installed. Per Tim Frost this new flow switch can be wired into the existing bell on the existing house.
FIR-Aging Inspection12/2/201012/2/201012/2/2010 DONE
DetailsForrest France
Site work in progress
INSP-Sprinkler Rough-in9/28/20109/29/20109/30/2010PPART
DetailsForrest France
Overhead rough-in completed acceptable. Installation okayed for cover.
Issue and Print Permit  9/16/2010 DONE
Plan assigned to (Tim)9/8/2010 9/15/2010 DONE
DetailsTim Frost
9/15/2010 13:33:12 TRF - activity updated through activity FIRA22 from case FIR10-00447.
Plan resubmittals received  9/15/2010  
DetailsTim Frost
rec'd 3 sets
Sprinkler Plan Check9/15/2010 9/15/2010 PASS
DetailsTim Frost
Please, see attached comments.
There are NO annotations on the plans.
PLANS/APPL TAKEN TO FRONT DESK  9/15/2010 DONE
DetailsTim Frost
Inspection Record Card- Fire9/15/2010 9/15/2010 DONE
DetailsBarbara Stitt
Permit Ready to Issue  9/15/2010 DONE
DetailsBarbara Stitt
Telephone call  9/15/2010 DONE
DetailsBarbara Stitt
Left voice message for Keith Dilworth that permit is ready & fees due on 9-15-10 @ 3:35pm
Sprinkler Plan Check9/13/2010 9/13/2010 FAIL
DetailsTim Frost
Please, see attached comments.
There are annotations on the plans.
1st review completed  9/13/2010 DONE
DetailsTim Frost
Miscellaneous action  9/13/2010 DONE
Emailed review to contractor.
Telephone call  9/13/2010 DONE
left vm for shaun at ###-#### - permit denied - needs to be picked up and resubmitted
Application received  9/8/2010  
Pending Assignment by SAM9/8/2010 9/8/2010 DONE
DetailsAlexandra L. DeYoung
9/8/2010 09:26:32 ALR - activity updated through activity FIRA158 from case FIR10-00447.