Permit Information
Permit NumberFIR10-00494
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 12000 W EXECUTIVE DR
Project NameScentsy at EDOP
Customer Number 
ePlanReviewNo
Description
The Fire Sprinkler Scope of work consists of changing portions of two existing systems to group A plastic storage on racks. The storage is Styrofoam packing material. Storage is 25’ high and the maximum building height is 32’. There are no solid shelves. Aisle widths shall be 3.5’ or greater. The existing control mode sprinklers are being changed to ESFR sprinklers. A new fire pump is being provided rated at 1250 Gpm @ 80 Psi. A draft curtain is shown separating the control mode sprinklers from the ESFR sprinklers.


Building Department Scope:

(Shell & Core – Fire Pump Room) Permit is to upgrade an existing fire riser room to be fully rated and comply with the other provisions of a Fire Pump Room (Last occupied by BMC West Door Plant). Approval contingent upon adhering to the approved plans on file. Work to include: construction of interior non-bearing walls to create the rated fire pump room, installation of new accessible door / hardware, installation of new mechanical vents, and finishes in compliance with chapter 8 of the 2006 IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. Any racking installed exceeding 8 ft. in height will require a separate racking permit. **TLW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  6/8/2011 DONE
Sent to records for scanning.
INSP-Final Inspection3/28/20113/28/20113/28/2011PPASS
DetailsTroy Cobbley
permit finaled
INSP-Final Inspection2/16/20112/16/20112/16/2011PCANC
DetailsTroy Cobbley
I spoke to Jeff on the phone about the remaining items which are test papers, ventilation and emergency lighting in the pump room.
INSP-Sprinkler Rough-in/Hydro2/9/20112/9/20112/9/2011PPASS
DetailsTroy Cobbley
Hydro test passed. The 12 missing uprights have been added and the additional upright in the fire pump room has been provided. These items can be removed from the previous correction notice.
INSP-Final Inspection2/4/20112/7/20112/7/2011PCANC
DetailsTroy Cobbley
Permit is not ready for final. See "rough-in" inspection notes.
INSP-Sprinkler Rough-in/Hydro2/4/20112/7/20112/7/2011PFAIL
DetailsTroy Cobbley
See the city approved plans/notes for items marked. They include pump room ventilation, pump room emergency lighting, additional sprinkler coverage in the pump room and 12 missing ESFR heads near the pump room and a hydro test.
INSP-Conference1/8/20111/11/20111/12/2011PPASS
DetailsTroy Cobbley
Certification of the fire pump passed. No other items inspected at this time.
Sprinkler Plan Check1/7/2011 1/7/2011 PASS
DetailsTim Frost
Please, see attached comments.
There are NO annotations on the plans.
PLANS/APPL TAKEN TO FRONT DESK  1/7/2011 DONE
DetailsTim Frost
Inspection Record Card- Fire1/7/2011 1/7/2011 DONE
DetailsPatricia Smith
Telephone call  1/7/2011 DONE
t/c w jeff packham - permit ready and fees given
Permit Ready to Issue  1/7/2011 DONE
Details
Issue and Print Permit  1/7/2011 DONE
Plan assigned to (Tim)10/5/2010 1/7/2011 DONE
DetailsTim Frost
Plan resubmittals received  1/6/2011 DONE
DetailsTisha Gallop
received three copies of application, submittal binder and plans; routed to Fire Review.
Miscellaneous action  12/7/2010 DONE
Spinkler permit is unable to be issued until a certificate of occupancy has been approved and issued to tenant.

Parcel has been lifted. Disregard above.
Early Start  10/29/2010 PASS
Please, see attached letter.
Sprinkler Plan Check10/12/2010 10/12/2010 FAIL
DetailsTim Frost
Please, see attached comments.
There are NO annotations on the plans.
1st review completed  10/12/2010 DONE
DetailsTim Frost
Telephone call  10/12/2010 DONE
t/c w jeff packham at ###-#### - permit denied - needs to be picked up and resubmitted
Application received  10/5/2010