Permit Information
Permit NumberFIR10-00544
StatusFinaled
Name FIRE SENTRY SYSTEMS
Site Address 1500 W SHORELINE DR
Project NameSt. Lukes Business Center
Customer Number 
ePlanReviewNo
Description
This fire alarm permit is to add notification to existing NAC panel #2, circuit #23 to accommodate a tenant improvement.

Associated building permit: BLD10-01976 (St. Luke’s Business Center - Cashier Area) This building is fully sprinklered. Project involves select interior non-bearing, non-structural demolition within a 2,200 sq. ft. portion of existing 93,490 sq. ft. office building. Existing building area, occupancy use group or occupant load will not be changed as a result of this remodel. Work includes construction of interior walls to define new office, work area and reduce waiting room size; install new millwork, 2-3' x 7' solid wood doors, interior finishes and modifications to electrical, mechanical, fire suppression and alarm systems, all per reviewed plans, red-line notes on plans and attached plan review comments/conditions attached to reviewed plans from all reviewing agencies. NOTE: Separate applications, plans and permits are required for sprinkler system and alarm modifications or additions as regulated by the Fire Dept. BEFORE any work on systems can begin. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  12/2/2010 DONE
Plans taken to records for scanning.
INSP-Final Inspection11/19/201011/19/201011/22/2010PPASS
DetailsForrest France
Correction items finished, inspection passed. Fire alarm permit finaled.
INSP-Final Inspection11/15/201011/16/201011/17/2010PFAIL
DetailsForrest France
Noted one H/S in need of repair, spacing needs adjusted per plan annotations, horns must be in compliance with the temporal pattern per adopted standards.
Issue and Print Permit  11/12/2010 DONE
DetailsBarbara Stitt
Plan assigned to (Stephanie)10/29/2010 11/10/2010 DONE
DetailsStephanie L. Cobbley
1st review completed  11/10/2010 DONE
Alarm Plan Check11/10/2010 11/10/2010 PASS
DetailsStephanie L. Cobbley
Plans approved with redlines and review comments
PLANS TAKEN FRONT DESK ALARM  11/10/2010 DONE
Approved redlined plans available at front counter
Inspection Record Card- Fire11/10/2010 11/10/2010 DONE
DetailsPatricia Smith
Telephone call  11/10/2010 DONE
t/c w john - permit ready and fees given
Permit Ready to Issue  11/10/2010 DONE
Details
Application received  10/29/2010