Permit Information
Permit NumberFIR11-00041
StatusFinaled
Name SIMPLEX GRINNELL
Site Address 1055 N CURTIS RD
Project NameSt Alphonsus south tower
Customer Number 
ePlanReviewNo
Description
This quick permit is to provide one chime/strobe to an existing system due to a tenant improvement. There are no written review comments. Approval is subject to field measurement of the EOL voltage drop. For appliances with an operating voltage range of 16V – 33V, the minimum acceptable voltage is 19.6V with the AC power off. Any measurement below this voltage will be considered insufficient to run the NACs at the end of useful battery life of 20.4V. UL 864, Standard for Control Units for Fire Signaling Systems. The installing contractor shall have available at final inspection a voltage meter and measure end of line voltages; witnessed by the field inspector. Associated building permit BLD10-01733 (ST ALPHONSUS - SOUTH TOWER - 1st FLR - Hyperbaric Chamber Remodel) Permit is to remodel a 574 square foot office area within an existing hospital for two Hyperbaric Chambers. Approval contingent upon adhering to the approved plans on file. Work to include: installation of hyperbaric chambers, installation of new oxygen piping, installation of new accessible counter, installation of new electrical, and finishes in compliance with chapter 8 of the 2006 IBC. This building is fully fire sprinklered any alterations or modifications to the sprinkler system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA #13 as regulated by the fire department. Racking that exceeds 8 ft. in height requires a separate Building Permit be submitted and approved before installation. **TLW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  2/9/2011 DONE
Plans taken to records for scanning.
INSP-Final Inspection2/1/20112/1/20112/1/2011PPASS
DetailsTroy Cobbley
Permit finaled
Issue and Print Permit  1/25/2011 DONE
Application received  1/21/2011  
Plan assigned to (Stephanie)1/21/2011 1/21/2011 DONE
DetailsStephanie L. Cobbley
Plan assigned to (Stephanie)1/21/2011 1/21/2011 DONE
DetailsStephanie L. Cobbley
1st review completed  1/21/2011 DONE
Alarm Plan Check1/21/2011 1/21/2011 PASS
DetailsStephanie L. Cobbley
Quick permit approved - no written review comments.
PLANS TAKEN FRONT DESK ALARM  1/21/2011 DONE
Approved quick permit plans available at front counter.
Inspection Record Card- Fire1/21/2011 1/21/2011 DONE
DetailsPatricia Smith
Telephone call  1/21/2011 DONE
left vm for charlie - permit ready and fees given
Permit Ready to Issue  1/21/2011 DONE
Details