Permit Information
Permit NumberFIR11-00046
StatusFinaled
Name SIMPLEX GRINNELL
Site Address 800 W IDAHO ST Unit: 112
Project NameTHE MODE BUILDING
Customer Number 
ePlanReviewNo
Description
This quick permit is to temporarily remove the notification devices and then place back in the original locations, to remove existing hood suppression system connections, and to add a duct detector. There are redlines, but no written review comments. Approval is subject to field measurement of the EOL voltage drop. For appliances with an operating voltage range of 16V – 33V, the minimum acceptable voltage is 19.6V with the AC power off. Any measurement below this voltage will be considered insufficient to run the NACs at the end of useful battery life of 20.4V. UL 864, Standard for Control Units for Fire Signaling Systems. The installing contractor shall have available at final inspection a voltage meter and measure end of line voltages; witnessed by the field inspector
Associated building permit: BLD10-02905 (ASPEN LEAF FROZEN YOGURT) This building is fire sprinklered to substitute for 1-hr fire-resistive construction. An automatic sprinkler system shall be required in the proposed walk-in freezer. Remodel for a new assembly frozen yogurt tenant in an existing 4,008 sq. ft. space on first floor of existing building. This space was previously occupied by Osaka Japanese and Sushi restaurant. Work to include: interior demolition work per plans; construct new interior walls to create a new customer sales/dining area, a employee support room, a small office, and storage room; install new flooring, ceiling treatment, and wall treatment; install new plumbing, electrical, and plumbing distribution work from the existing units and panels; installation of exit signs and emergency lighting; removing an exterior door and replacing with storefront glazing; and finishes in compliance with chapter 8 of the 2006 IBC. This building is fully fire sprinklered any alterations or modifications to the sprinkler system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA #13 as regulated by the fire department. A new Certificate of Occupancy with the new occupant load total is required to be obtained after all work has been inspected and approved and prior to tenant occupying this space. All work shall comply with the approved drawings, the plan review report, and all applicable codes. **SRZ**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary  4/26/2016 DONE
Case Summary  4/26/2016 DONE
Miscellaneous action  6/15/2011 DONE
Drawings taken to records for scanning.
INSP-Final Inspection2/25/20112/25/20112/25/2011APASS
DetailsForrest France
Corrections completed. Record of inspection recieved. Fire alarm permit finaled.
INSP-Final Inspection2/23/20112/24/20112/24/2011PPART
DetailsForrest France
Fire alarm work passed functional testing, final pending correct size sample tube/installation at the duct detector.
Issue and Print Permit  2/1/2011 DONE
Plan assigned to (Stephanie)1/27/2011 1/28/2011 DONE
DetailsStephanie L. Cobbley
Plan assigned to (Stephanie)1/27/2011 1/28/2011 DONE
DetailsStephanie L. Cobbley
1st review completed  1/28/2011 DONE
Alarm Plan Check1/28/2011 1/28/2011 PASS
DetailsStephanie L. Cobbley
Quick permit - approved with redlines - no written review comments.
PLANS TAKEN FRONT DESK ALARM  1/28/2011 DONE
Approved redlined plans available at front counter.
Permit Ready to Issue  1/28/2011 DONE
DetailsBarbara Stitt
Inspection Record Card- Fire1/28/2011 1/28/2011 DONE
DetailsBarbara Stitt
Telephone call  1/28/2011 DONE
DetailsBarbara Stitt
Called Charlie and told him that permit is ready & fees due on 1-28-11 @ 3:25pm
Application received  1/27/2011