Permit Information
Permit NumberFIR11-00168
StatusFinaled
Name ENTERPRISE ELECTRIC
Site Address 358 N BENJAMIN LN
Project NameADA COUNTY PARAMEDICS WAREHOUS
Customer Number 
ePlanReviewNo
Description
This fire alarm permit is to extend the fire alarm system from the main building located at 370 Benjamin (installed under FIR11-00010). Included in this permit scope of work is an annunciator, pull station, sprinkler monitoring modules, HVAC monitoring/shutdown, and transient/lightning protection between the buildings (see comment #1 below). The main building fire alarm panel is utilizing an AES RF radio for transmitting the fire alarm signals (installed under FIR11-00156).

Associated building permit: BLD10-01261 Ada County Paramedics Warehouse Maintenance and Repair Facility - To construct a new 7,410 square foot, one story vehicle maintenance, warehouse and office building. This building is constructed of masonry and wood framed exterior and interior walls and steel joist with metal roof deck. This permit also includes related site improvements. All construction per the approved plans and attached comment list. JCM
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  6/15/2011 DONE
Drawings taken to records for scanning.
INSP-Final Inspection4/21/20114/22/20114/22/2011APASS
DetailsForrest France
Correction items per last inspection verified for completion. Fire alarm permit finaled.
INSP-Final Inspection4/21/20114/21/20114/21/2011PFAIL
DetailsTroy Cobbley
All items tested ok but the signals sent out report a general fire and supervisory signals for both the 358 and 370 addresses. The signal has to be specific for the address. Signals need to be resent from both buildings to verify corrections. The duct smoke detector was missing the sample tube and was installed while I waited. The tamper switch on the PIV was installed backwards and wired backwards and was also repaired while I waited.
INSP-Final Inspection4/20/20114/21/20114/21/2011AFAIL
DetailsTroy Cobbley
Installation does not match plans. The modules that were to be removed are still installed. Also the the wire between the two buildings is supposed to meet requirements in NEC article 800 and it does not. No testing was performed.
Plan assigned to (Stephanie)4/8/2011 4/20/2011 DONE
DetailsStephanie L. Cobbley
1st review completed  4/20/2011 DONE
Alarm Plan Check4/20/2011 4/20/2011 PASS
DetailsStephanie L. Cobbley
Approved with redlines and review comments.
PLANS TAKEN FRONT DESK ALARM  4/20/2011 DONE
Approved redlined plans available at front counter.
Inspection Record Card- Fire4/20/2011 4/20/2011 DONE
DetailsPatricia Smith
Telephone call  4/20/2011 DONE
customer in lobby
Permit Ready to Issue  4/20/2011 DONE
Details
Issue and Print Permit  4/20/2011 DONE
Telephone call  4/19/2011 DONE
Spoke to Rob Ahten and requested a data sheet for the transient/lightning protection modules. He stated he would not be able to get it to me until tomorrow morning.
Telephone call  4/19/2011 DONE
Called Rob Ahten to let him know the part number he provided for the transient/lightning protection module is not listed for use with the Silent Knight Fire Alarm Panel and that he would need to get with the vendor to obtain the correct part/data sheet. In addition, I let him know he would also need to provide the transient/surge protection for the remote annunciator panel.
Application received  4/8/2011