Miscellaneous action | | | 9/23/2013 | | DONE |
Tim Frost
|
|
|
Sent to Records for scanning.
|
INSP-Final Inspection | 10/24/2012 | 10/24/2012 | 10/30/2012 | P | PASS |
Forrest France
|
|
|
Corrections finished. Fire sprinkler permit finaled.
|
INSP-Final Inspection | 10/22/2012 | 10/22/2012 | 10/30/2012 | P | PART |
Forrest France
|
|
|
Plan modifications and field install checked for equivalence.
|
INSP-Final Inspection | 10/17/2012 | 10/19/2012 | 10/30/2012 | A | PART |
Forrest France
|
|
|
Field verified corrections.
|
FIR-Aging Inspection | 7/3/2012 | 7/3/2012 | 7/3/2012 | | DONE |
Forrest France
|
|
|
|
CHANGE STATUS TO (ISS) | | | 5/3/2012 | | DONE |
Tisha Gallop
|
|
|
Paul picked up plan mod
|
Case Summary | | | 5/3/2012 | | DONE |
Tisha Gallop
|
|
|
|
Sprinkler Plan Check | 4/23/2012 | | 4/23/2012 | | PASS |
Tim Frost
|
|
|
Please, see attached comments.
There are NO annotations on the plans.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 4/23/2012 | | DONE |
Tim Frost
|
|
|
|
Inspection Record Card- Fire | 4/23/2012 | | 4/23/2012 | | DONE |
Barbara Stitt
|
|
|
|
CHANGE STATUS TO (ISS) | | | 4/23/2012 | | DONE |
Barbara Stitt
|
|
|
|
(F) Reprint permit | | | 4/23/2012 | | DONE |
Barbara Stitt
|
|
|
|
Telephone call | | | 4/23/2012 | | DONE |
Barbara Stitt
|
|
|
E-mailed paul that permit is ready & fees due on 4-23-12 @ 9:05am//BAS
|
Plan assigned to (Tim) | 4/20/2012 | | 4/23/2012 | | DONE |
Tim Frost
|
|
|
|
Plan resubmittals received | | | 4/20/2012 | | |
|
|
|
Plan Modification
|
INSP-Sprinkler Rough-in | 4/2/2012 | 4/3/2012 | 4/4/2012 | P | PART |
Forrest France
|
|
|
Previous C/N items verified for completion. Finished walkthrough for coverage adjustments at the overhead AMH tracks and cubbies. Noted missing coverage at the SW corner of the north half photo bay. Plan modifications pending.
|
INSP-Sprinkler Rough-in/Hydro | 3/28/2012 | 3/29/2012 | 3/30/2012 | A | PART |
Forrest France
|
|
|
System 4 overhead hydrostatic test passed. Completed re-inspection for relocated and added pendent heads at the AMH track areas. Noted missing hangers on three new arm-overs >2'.
|
INSP-Sprinkler Rough-in/Hydro | 2/28/2012 | 3/1/2012 | 3/2/2012 | P | PART |
Forrest France
|
|
|
Re-inspection for noted correction items at system 4 photo bay and link include: retainers at mains and branchlines secured; adjustments in pendent head locations at AMH track underway- overhead storage cubbies may also present obstruction issues when installed; seismic bracing completed; pendent heads at the link drop ceiling are matched with grid install to date. Plans will need revised to reflect field modifications at several areas.
|
INSP-Sprinkler Rough-in/Hydro | 1/12/2012 | 1/13/2012 | 1/13/2012 | P | FAIL |
Forrest France
|
|
|
Rough-in inspection completed for system # 4 clean link and photo bay. Noted items include missing retainers at several beam clamps on branchlines, 4" and 6" mains, missing hanger at arm-over, pendent heads are blocked or obstructed at numerous locations due to proximity to AMH brackets, flex head whips are not yet installed at various areas in the clean link, missing seismic bracing at the 6" main, secure EQ brace at the 4" main, added 90s at branchlines in the photo bay are not included in the calcs.- branch line restraint at these locations shall be provided per NFPA 13 9.3.6.4.
|
Fees Due Hold | 1/6/2012 | | 1/6/2012 | | DONE |
Rita DeYoung
|
|
|
|
Fees Due Hold | 12/31/2011 | | 1/5/2012 | | DONE |
Rita DeYoung
|
|
|
|
Fees Due Hold | 12/17/2011 | | 12/30/2011 | | DONE |
Patricia Smith
|
|
|
signed off per rita
|
Sprinkler Plan Check | 12/16/2011 | | 12/16/2011 | | PASS |
Tim Frost
|
|
|
Please, see attached comments.
There are NO annotations on the plans.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 12/16/2011 | | DONE |
Tim Frost
|
|
|
|
Permit Ready to Issue | | | 12/16/2011 | | DONE |
Barbara Stitt
|
|
|
|
Inspection Record Card- Fire | 12/16/2011 | | 12/16/2011 | | DONE |
Barbara Stitt
|
|
|
|
Telephone call | | | 12/16/2011 | | DONE |
Barbara Stitt
|
|
|
Called and left a message for Bob Knight that permit is ready & fees due on 12-16-11 @ 10:23AM
|
Issue and Print Permit | | | 12/16/2011 | | DONE |
|
|
|
|
Miscellaneous action | | | 12/12/2011 | | PEND |
|
|
|
Spoke with Jim Darr. He called back after saying he was providing trapeze hangers for the main. He now says he does not want to trapeze the mains. I told him if he wanted to hang the main from one truss that I would need a letter from a mechanical engineer indicating the truss will support the main. The project is on hold pending this information.
|
Plan resubmittals received | | | 12/9/2011 | | |
|
|
|
Received resubmittals 12-8-11
|
Plan assigned to (Tim) | 9/22/2011 | | 12/6/2011 | | DONE |
Tim Frost
|
|
|
|
Miscellaneous action | | | 9/29/2011 | | DONE |
|
|
|
Micron picked up denied plans
|
Sprinkler Plan Check | 9/28/2011 | | 9/28/2011 | | FAIL |
Tim Frost
|
|
|
Please, see attached comments.
There are NO annotations on the plans.
|
1st review completed | | | 9/28/2011 | | DONE |
Tim Frost
|
|
|
|
Miscellaneous action | | | 9/28/2011 | | DONE |
Tim Frost
|
|
|
Emailed review to contractor
|
Telephone call | | | 9/28/2011 | | DONE |
|
|
|
t/c w tanner - permit denied - needs to be picked up and resubmitted
|
Telephone call | | | 9/26/2011 | | DONE |
|
|
|
Called John Ronan at Micron to discuss the design philospy of this project. Left a voice mail for him to call me back. The project is on hold pending his phone call.
|
Application received | | | 9/22/2011 | | |
|
|
|
|
INSP-Conference | 2/1/2012 | 2/3/2012 | | A | |
Forrest France
|
|
|
Phone #: ###-#### >> Inspection requested via web by Alicia Pauley
|