Permit Information
Permit NumberFIR11-00547
StatusFinaled
Name SIMPLEX GRINNELL
Site Address 11311 W CHINDEN BLVD
Project NameHP BLDG B1-RESTRM RENNOVATION
Customer Number 
ePlanReviewNo
Description
This quick permit is to relocate existing horn/strobes and add two new strobe only devices to an existing NAC to accomodate a tenant remodel. Approval is subject to field measurement of the EOL voltage drop. For appliances with an operating voltage range of 16V – 33V, the minimum acceptable voltage is 19.6V with the AC power off. Any measurement below this voltage will be considered insufficient to run the NACs at the end of useful battery life of 20.4V. UL 864, Standard for Control Units for Fire Signaling Systems. The installing contractor shall have available at final inspection a voltage meter and measure end of line voltages; witnessed by the field inspector. There are no written review comments. Associated building permit: BLD11-02036 (HP BLDG B1 - RESTROOM RENNOVATION) This permit is for the up grade of eight restrooms four mens and four womens all in bldg 1. Four on the second floor and four on the first floor. the 1st floor ne wonens will also have the showers upgaded.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  1/20/2012 DONE
Plans taken to records for scanning.
INSP-Final Inspection11/21/201111/22/201111/22/2011APASS
DetailsTroy Cobbley
Permit finaled
Miscellaneous action  11/21/2011 DONE
Made a copy of the approved plans per contractor's request due to them losing the job-site copy. I placed the copy at the front counter for the contractor to pick up.
INSP-Final Inspection11/2/201111/3/201111/3/2011AFAIL
DetailsTroy Cobbley
The effects of the strobe can not been seen in all areas of the restroom. Relocate or add additional devices.
Issue permit  10/6/2011 DONE
Payment received via Govolutions
Miscellaneous action  10/6/2011 DONE
DetailsTisha Gallop
picked up plans
Inspection Record Card- Fire10/6/2011 10/6/2011 DONE
DetailsPatricia Smith
Telephone call  10/6/2011 DONE
t/c w dante - permit ready and fees given
Permit Ready to Issue  10/6/2011 DONE
Details
Application received  10/5/2011  
Plan assigned to (Stephanie)10/5/2011 10/5/2011 DONE
DetailsStephanie L. Cobbley
Plan assigned to (Stephanie)10/5/2011 10/5/2011 DONE
DetailsStephanie L. Cobbley
1st review completed  10/5/2011 DONE
Alarm Plan Check10/5/2011 10/5/2011 PASS
DetailsStephanie L. Cobbley
Quick permit approved with redlines. There are no written review comments.
PLANS TAKEN FRONT DESK ALARM  10/5/2011 DONE
Approved redlined quick permit plans are available at front counter.